KitchenAid W10267109C Venting Methods, Example vent system - 6 15.2 cm, Roof Venting, Vent Piece

Models: W10267109C

1 36
Download 36 pages 47.23 Kb
Page 7
Image 7
Venting Methods

Venting Methods

This range hood is factory set for venting through the roof or through the wall.

The vent system needed for installation is not included. A 6" (15.2 cm) round vent system is recommended.

Roof Venting

Wall Venting

Roof VentingB

Example vent system - 6" (15.2 cm)

Wall cap

90˚ elbow

6 ft (1.8 m)

3 ft

(0.93 m)

A

A

Example vent system - 6" (15.2 cm)B

Maximum Length

= 35 ft (10.7 m)

1

- 90° elbow

=

5 ft (1.5 m)

1

- wall cap

=

0 ft (0 m)

9 ft (2.8 m) straight

=

9 ft (2.8 m)

 

 

System length

= 14 ft (4.3 m)

Non-Vented (recirculating) Installations Through the Soffit/ Cabinet

A. 6" (15.2 cm) vent through

A. 6" (15.2 cm) vent through

the roof

the wall

B. Roof cap

B. Wall cap

Calculate Vent System Length

The recommended vent system is 6" (15.2 cm) round vent with a maximum length of 35 ft (10.7 m). For the best performance, use no more than three 90° elbows.

To calculate the length of the system, add the equivalent feet (meters) for each of the vent pieces used in the system.

Vent Piece

6" (15.2 cm)

45° elbow

2.5 ft

 

(0.8 m)

If it is not possible to vent cooking fumes and vapors to the outside, the range hood can be used in the non-vented (recirculating) version, using charcoal filters. Recirculation Kit Part Number 4396565 is available from the dealer or an authorized parts distributor. Damper installation is not required.

A

A

 

B

B

 

 

C

 

F

D

D

F

 

E

E

90° elbow

5.0 ft

A. Ceiling

D. 6" (15.2 cm) vent

 

(1.5 m)

B. Vent cover

E. Range hood

 

 

C. Soffit

F. Cabinet

 

 

 

 

7

Page 7
Image 7