Replacements and Installations
SM4530-1 – 30APR96 11
Replacing the LAMP MODULE RECEPTACLE
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3] Cut and remove the necessary WIRE TIES.
[4] Remove the 2
Torx
SCREWS on the left side of the LOWER LIGHT BAFFLE ASSEMBLY.
[5] Loosen the
Torx
SCREW on the right side of the LOWER LIGHT BAFFLE ASSEMBLY approximately 1/2 way.
[6] Lift and remove the LOWER LIGHT BAFFLE ASSEMBLY.
[7] Lift the GRILLE ASSEMBLY up.
[8] Remove the 2 long
Torx
from the BLOWER COVER ASSEMBLY.
[9] Lift the BLOWER COVER ASSEMBLY up.
[10] Lift and move the PREHEAT DUCT up.
[11] Toremove the LAMP MODULE RECEPTACLEfrom the PREHEAT DUCT,compress the 2 TABSon the LAMP
MODULE RECEPTACLE.
Installing the LAMP MODULE RECEPTACLE
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LAMP MODULE RECEPTACLE in reverse order.
A100_0016HA SCREW (not shown)
RECEPTACLE
LAMP MODULE
ASSEMBLY
BLOWER COVER
SCREW (2)
PRE-HEAT DUCT
SCREW (2)
LOWER LIGHT BAFFLE
A100_0016HCA