Replacements and Installations
SM4530-1 – 30APR96 7
Installing the FAN SHAFT ASSEMBLYImportant
When installing the FAN and MECHANISM BELTS, install the MECHANISM BELT on the small MOTOR PULLEY,
and the FAN BELT on the large MOTOR PULLEY.
[1] Do the removal procedure for the FAN BELT and SHAFT in reverse order.
Replacing the MOTORWarning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER
HOUSING ASSEMBLY.
[3] Disconnect all wires from the MOTOR.
[4] Cut the 2 WIRE TIES on the SMALL CIRCUIT
BOARD between the MOTOR and MECHANISM
ASSEMBLY.
[5] Disconnect the 2 wires from the CYCLE
SOLENOID on the SMALL CIRCUIT BOARD.
[6] Pull the SMALL CIRCUIT BOARD up.
[7] Disconnect all wires on the MOTOR.
[8] Remove3
Hex
1/4 in. SCREWS from the MOTOR.
[9] Lift the MOTORup to allow access to the FAN and
MECHANISM BELTS.
[10] Remove the FAN and MECHANISM BELTS from
the MOTOR PULLEY.
[11] Remove the MOTOR.
A091_4015BA
A091_4015BCA
MECHANISM BELT
FAN BELT
A091_4016GA
MOTOR
SCREW (3)
A091_4016GCA