Adjustments

Adjustment Specification

Use TL-1744 to check that the CLAMP PAD ASSEMBLY moves forward and backward.

Adjusting the CLAMP PAD ASSEMBLY

SCREW

NUT

CLAMP PAD

ASSEMBLY

A091_4041GCA

A091_4041GA

Warning

Dangerous Voltage

[1]Disconnect the main power.

Important

If the CLAMP ASSEMBLY has a COIL SPRING on the ADJUSTMENT SCREW, remove it. This will make the adjustment easier.

It is necessary to make a FAN COVER TOOL. See the Tools section.

[2]Do the removal for the LOWER HOUSING ASSEMBLY.

[3]Install the FAN COVER TOOL over the FAN area and the LAMP MODULE. See the Tools section.

[4]Connect the REMOTE CONTROL ASSEMBLY EC-3 to the REMOTE RECEPTACLE.

[5]Connect the main power.

[6]Loosen the NUT on the CLAMP PAD ASSEMBLY.

[7]Energize the REMOTE FOCUS in either direction.

[8]Rotate the SCREW on the CLAMP PAD ASSEMBLY to adjust the pressure of the REMOTE FOCUS CLAMP on the CLAMP PAD ASSEMBLY until the CLAMP PAD ASSEMBLY does not move.

[9]Release the REMOTE FOCUS.

[10]Tighten the NUT on the CLAMP PAD ASSEMBLY.

[11]Install the AUTO-FOCUS GAUGE TL-1744 in the MECHANISM GATE. The CLAMP PAD ASSEMBLY should move forward and backward using TL-1744. If not, adjust the SCREW on the CLAMP PAD ASSEMBLY again; the CLAMP PAD ASSEMBLY adjustment is too tight and not correct.

Adjustment Specification

The PRESSURE PAD should be aligned with the DARK SHUTTER.