SERVICE MANUAL

Adjusting the NULL

 

light path

 

T-BAR

 

TL-3003

 

NULL position

PROJECTION

TAB

LENS

 

AUTO-FOCUS

CLAMP LEVER

 

TARGET SLIDE

A091_4031BCA

PAD

A091_4031BA

TL-3002

 

Warning

Dangerous Voltage

[1]Disconnect the main power.

[2]Do the removal for the LOWER HOUSING ASSEMBLY.

Important

It is necessary to make a FAN COVER TOOL. See the Tools section.

If you cannot obtain the NULL position after doing the adjustment approximately 3 times, go to the adjustment procedure for the PHOTOCELL.

[3]Install the FAN COVER TOOL over the FAN area and the LAMP MODULE. See the Tools section.

[4]Energize the projector.

[5]Set the projector to the LO-LAMP position.

[6]Install and hold the AUTO FOCUS TARGET SLIDE TL-3002 until it is fully seated in the GATE MECHANISM.

[7]Look through the PROJECTION LENS hole and observe the focus light path on the AUTO-FOCUS TARGET SLIDE TL-3002. Check that the light image is correct. If not, do the Adjusting the FOCUS LIGHT PATH.

[8]Check that the TAB on the CLAMP PAD ASSEMBLY is in the NULL position. If the TAB is not in the correct position, do the adjustment procedure for the NULL.

[9]Bend the PHOTOCELL BRACKET to move the NULL in the center; use T-BAR TL-3003.

Adjustment Specification

Use TL-3002 and FAN CAP 232729 to check the adjustment of the PHOTOCELL.

32

30APR96 – SM4530-1

Page 32
Image 32
Kodak KKE PLUS, KKA, JAMT, J-E PLUS, E-PLUS SLIDE, ATS, BR Adjusting the Null, Projection TAB Lens AUTO-FOCUS, Target Slide