3. Settings and adjustments for shooting

Lens settings

Set according to whether the used lens to be used is an auto-iris lens or a manual lens.

Set the used Lens

Set the [IRIS MODE] on the [EXPOSURE] screen. ( page E33)

AUTO : Setting when auto-iris lens is used in auto mode.

MANUAL : Set when using a manual lens, using an auto-iris

lens in MANUAL or no lens.

* If the auto-iris lens cable is not connected to

the [LENS] connector, the setting automatically becomes “MANUAL”.

(Default setting: AUTO)

Monitor adjustment

The colour contrast and brightness are adjusted whilst, built-in test signals of the camera are being displayed on the PC monitor.

[ANALOG OUT]

[IEEE1394]

ANALOG OUT

IEEE1394

 

LENS

 

 

MD

 

CONTROL

DC IN

REMOTE

POWER

 

SEE INSTRUCTION MANUAL

Inside window

 

UP/AW

MENU

SET

 

DOWN

1 2

3 4

Default Setting Switch

1. Connect the [ANALOG OUT] connector or the [IEEE1394] connector to the PC.

2. Set the function setting switch NO.1 on the switch panel on the side of the KY-F1030 to “ON”.

ON

OFF 1 2 3 4

3. Turn ON the KY-F1030, and then start the PC.

*When connecting through the [IEEE1394] connector, power is supplied from the PC.

4.Adjust the monitor.

MEMO

For how to adjust, see the instructions for the employed monitor.

The peak level of the test signal is set to 0.7V from the fac- tory. To use 0.57V, change the setting by [TEST PATTERN]

[LEVEL] on the [SYSTEM SETTING] screen.

page E40 TEST PATTERN

E21

Page 25
Image 25