1. Introduction (continued)

Pin configurations of connectors

DC IN terminal (Mini DIN 8-pin, female)

 

 

 

7

 

 

 

8

 

 

 

 

 

6

 

5

 

3

 

 

2

4

 

 

1

 

 

 

 

 

 

 

Pin no.

 

 

Signal name

 

 

 

 

 

 

 

 

1

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LENS terminal (Metal 12-pin, female)

 

9

10

1

 

 

 

8

 

2

 

7

 

3

 

6

 

4

 

12

5

11

Pin no.

 

Signal name

 

 

 

 

1

NC

 

 

2

NC

 

 

 

 

 

 

3

GND

 

 

4

NC

 

 

 

 

5

IRIS CONTROL

6

12V DC 400mA max.

 

 

7

IRIS POSITION

8

IRIS AUTO /MANU

 

 

 

 

9 to 12

NC

 

 

 

 

 

 

CAUTION

Use device whose current consumption is max.

400 mA or less.

REMOTE terminal (Metal 10-pin, female)

 

8

1

 

7

2

 

10

9

 

6

3

 

5

4

Pin no.

 

Signal name

1

A. WHITE L active

2

TRG IN L active

3

WEN L active 3.3V(p-p)

4

FLASH

 

5

NC

 

6

RS-SDI

 

7

RS-SDO

8

GND

 

9

12V

 

10

OPERATION

CAUTION

Consult your JVC dealer concerning the re- mote terminal connection.

Remote cable must use shielded cable. Outer shield of remote cable must to connect 10-pin connector outer metal shell.

Do not input the external trigger during the first 5 seconds after the power is turned ON.

Terminal

 

I/O

 

Conditions

name

 

 

 

 

 

 

 

 

 

2 TRG IN

IN

• Contact point

 

• 3.3V CMOS

 

recommended

 

Schmidt Trigger

• Maximum rated

 

Pull-up to 3.3V at

 

voltage: 5.3V

 

 

4.7k

H level: 2.4 ~ 5.0V

 

 

 

L level: 0 ~ 0.5V

 

 

 

• Pulse width:

 

 

 

 

130 s or higher

 

 

 

 

3 WEN

OUT

 

 

 

3.3V (p-p)

 

 

 

 

negative polarity

 

 

 

 

 

4 FLASH

OUT

• Maximum rated

 

Open collector

 

current: 150mA

 

 

 

• Maximum rated

 

 

 

 

voltage: 12V

 

 

 

 

 

E12

Page 16
Image 16
JVC KY-F1030U Pin configurations of connectors, DC in terminal Mini DIN 8-pin, female, Lens terminal Metal 12-pin, female