E33

Contents
Switched in accordance with the used lens.
AUTO: When using auto-iris lens.
MANUAL: When using manual iris lens.
Lens not mounted
When using manual iris while auto-iris lens
is mounted.
*When the auto-iris lens cable is not connected to the
[LENS] connector, the setting automatically becomes
MANUAL.
Used to adjust the video level when auto-iris, ALC and
EEI are used,
Increasing the value: Raises the level
Decreasing the value: Lowers the level
Used to set the iris level when the IRIS MODE is set to
MANUAL.
Increasing the value: Opens the iris
Decreasing the value: Closes the iris
Menu contents
1 : EXPOSURE: .................
Used for settings related to the video level, such as iris, shutter, sensitivity, etc.
2 : WHITE BALANCE:........ Used to make settings for color temperature and white balance.
3 : PROCESS:.................... Used to make settings for detail compensation, gamma, master
black, flare compensation, Auto Black Level (ABL), etc.
4 : LENS :...........................
Sets the control method for the lens iris and lens focus, and zoom control method.
5 : SYSTEM SETTING:...... Sets the screen display method and level of test pattern.
EXPOSURE screen
Item
IRIS MODE
Set Value
[AUTO]
MANUAL
-128
-127
:
[NORMAL]
:
126
127
[FULL]
SQUARE
SPOT
0
1
[128]
254
255
[ ] indicates the factory setting
FULL SQUARE SPOT
MEMO
During selection of
the detection area,
the detection area is
shown on the
screen connected to
the analog output.
AE LEVEL
AE AREA
IRIS
LEVEL
Detection
area Detection
area
Detection area
MEMO
---- is displayed when auto-iris, ALC, and EEI are all set to
not operate.
Used to set the detection area for auto-iris. Switch
the setting in accordance with the conditions of use.