IMPORTANT INSTRUCTIONS

READ AND SAVE FOR THE

CONSUMER

WARNING: Risk of scalding or other severe injury.

Before completing installation, the installer must set the maximum water temperature setting of this valve to minimize the risks associated with scalding hazards according to ASTM F 444.

Do not install a shut-off device on either outlet of this valve. The installation of any such device may create a cross-¯ow condition at the valve and affect the water temperature.

Factors that change the temperature of the water supplied to the valve, such as seasonal water temperature changes, and water heater replacement or servicing, will change the maximum water temperature supplied by the valve and may create a scalding hazard.

The pressure-balanced valve will not compensate for changes in the water supply temperature; adjust the maximum water temperature setting of this pressure-balanced valve when such changes occur.

Pressure-balanced valves may not provide protection against scalding if there is a failure of other temperature-limiting devices elsewhere in the plumbing system.

The installer is responsible for installing the valve and adjusting the maximum water temperature of this valve according to instructions.

This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.

If you do not understand any of the installation or temperature adjustment instructions in this document, in the United States please contact our Customer Service Department at 1-800-4-KOHLER.Outside the U.S., please contact your distributor.

IMPORTANT NOTICE TO INSTALLERS! Please ®ll in the blanks in the information box in the Homeowners Guide and on the valve label. Retain the Homeowners Guide for future reference.

1025255-2-C

2

Kohler Co.

Page 2
Image 2
Kohler K-T16139, K-T16115, K-T16116, K-T16113, K-T16117, K-T16114, K-16217, K-16214, K-16213 manual Important Instructions