Configuring the FC-8 Wi-Fi - RS-232 Bridge

Table 3: FC-8 Serial Net Configuration Parameters

Parameter

Possible Values

Notes

MAC Address

 

Ethernet hardware address (read-only)

Bootblock Version

 

For technical use (read-only)

Serial Number

 

Factory serial number of the device (read-

 

 

only)

Web Server Status Message

Must be I/OK

(read-only)

Firmware Version

Must end with b17 or above

(read-only)

Hardware Version

 

For technical use (read-only)

Active IP Address

192.168.3.2 (Default)

Active IP address of the FC-8

Subnet Address

255.255.255.0 (Default)

 

IP Gateway

0.0.0.0 (Default)

 

Wireless LAN SSID

Alpha-numeric

Network name (SSID)

 

Kramer-FC8 (Default)

 

 

An ad-hoc network must

 

 

begin with the character “!”

 

IP Registration Host Server

nnn.nnn.nnn.nnn:ppp

The Registration Host Server Name is used

Name

Where:

to locate and establish a connection after

 

nnn.nnn.nnn.nnn =

FC-8 establishes an Internet session

 

a server name or IP address

connection as a result of an explicit

 

 

command or as a result of automated

 

ppp = 0..65535

Internet session establishment procedures.

 

The dynamically assigned IP address is sent

 

 

 

If Registration Host Server

to the server in ASCII form, after which the

 

socket is closed. See Socket IP Registration.

 

Name is empty, no IP

It is assumed that the host server is

 

registration server name is

"listening" on port number.

 

defined.

FC-8registers itself by opening a socket to a

 

 

 

192.168.3.1 (Default)

registration server and sending its ID

 

information and current IP address. When

 

 

the Registration Host Server Name

 

 

parameter contains a value, the FC-8

 

 

establishes a socket to the server defined in

 

 

Registration Host Server Name during the

 

 

registration procedure. When a socket is

 

 

established, FC-8transmits its ID information

 

 

and current IP address in the following

 

 

format:

 

 

FC-8-<D/L/S> S/N:<RP5> version: <RP1>

 

 

HN:<HSTN> IP:<IPA or RRRL> Port:<LPRT

 

 

or 80 or 0>”

 

 

The registration socket is then closed.

SerialNet Listening Port

0 to 64000

 

 

10000 (Default)

 

Socket Type

0 – TCP (Default)

 

 

1 – UDP

 

Host Server & Port

nnn.nnn.nnn.nnn:ppp

To configure the FC-8as an active station,

 

 

see section 6￿ .4.

Security Type

0 ± N

No security

 

1 ± WEP64

 

 

2 ± WEP128

 

 

3 ± WPA

 

 

4 ± WPA2

 

 

 

 

10

 

KRAMER: SIMPLE CREATIVE TECHNOLOGY

 

 

Page 14
Image 14
Kramer Electronics user manual FC-8 Serial Net Configuration Parameters