Your VP-128H Matrix Switcher
3
 A passive two BNC sync loop - useful to ensure deterministic switching
1
 Two VP-128H units can be cascaded
Control the VP-128H via the front panel buttons, or remotely:
 Via the 10 Base T network of RC-1616 panels
2
or RS-232 serial
commands transmitted by a touch screen system, PC, or other serial controller
3.2 About the RC-1616
The RC-1616 Remote Control is ideal for sophisticated control from various
locations via the 10 Base T network. You can connect up to 512 RC-1616
Remote Control panels to one router: 256 XY panels and 256 single bus panels.
3.3 Achieving the Best Performance
To achieve the best performance:
 Connect only good quality connection cables, thus avoiding interference,
deterioration in signal quality due to poor matching, and elevated noise levels
(often associated with low quality cables)
 Avoid interference from neighboring electrical appliances and position
the VP-128H / RC-1616 away from moisture, excessive sunlight and dust
4 Your VP-128H Matrix Switcher
The VP-128H Matrix Switcher can be used:
 With the front panel and rear panel intact, see section 4.1
 Without the front panel (the front panel is blocked off), but with the rear
panel intact, see section 4.2
 With the VP-128H front panel detached, which functions as a local
control panel, see section 4.3
4.1 The VP-128H with the Front Panel and the Rear Panel Intact
Figure 1 and Table 1 and Table 2 define the front
3
and rear panels of the
VP-128H Matrix Switcher:
1 Connect video with sync to either BNC. If desired, use the second BNC to loop the signal to another device
2 Network control will allow more powerful panels to store in the panel setup and recall schemes that are tailored to the
configuration of the panels controls. An entire router configuration can be sent to the router from the panel in under one
millisecond
3 The same switch assemblies and metalwork that make up the front panel are used on the remote control panel. You can
connect up to 512 remote control panels to one router: 256 XY panels and 256 single bus panels