KTI Networks 2028 manual Port Connecting to, Factory Default Settings, Important Note

Models: 2028

1 21
Download 21 pages 12.98 Kb
Page 15
Image 15

When a operation mode is accepted by the remote device, the mode is used for the data transfer between the port and the connected device. Full-duplex opera- tion enables two devices to transfer data bi-directionally at the same time.

For connecting to a hub, refer to the following table for the switch setting:

Port

Connecting to

Port #1 - #8

10BASE-T hub

Port #9, Port #10

10BASE-T hub

Port #9, Port #10

100BASE-TX hub

Setting

Half duplex (D=Off) Auto-negotiation mode Auto-negotiation mode

For connecting to other device such as another switch or computer, refer to the following table:

Port

Connecting to

Port #1 - #8

Half-duplex device

Port #1 - #8

Full-duplex device

Port #9, Port #10

Non-NWay device

Port #9, Port #10

NWay device

Setting

Half duplex (D=Off) Full duplex (D=On) Manual mode Auto-negotiation mode

Factory Default Settings

All switches are set to OFF position when the switch unit is shipped out from factory. That means Port #1 to Port #8 are at half-duplex mode and Port #9 and Port #10 are at auto-negotiation mode.

Important Note:

As long as any change on the settings of the switch groups is made, you must turn the power to the switch unit off and turn it on again to make the change take effect.