3.3 10/100BASE-TX Switched Ports

This section applies to the 10/100BASE-TX Port #9 and expansion slot Port #10 pre-configured with a 10/100BASE-TX port module. Use the crossover switch to set the type of RJ-45 connector as follows:

The following table lists the devices to which the ports can connect:

Device connected

Crossover SW

Computer 10BASE-T port

X setting

10BASE-T hub port (I type)

X setting

10BASE-T hub port (X type)

I setting

10BASE-T switched port (I type)

X setting

10BASE-T switched port (X type)

I setting

100BASE-TX hub port (I type)

X setting

100BASE-TX hub port (X type)

I setting

100BASE-TX switched port (I type)

X setting

100BASE-TX switched port (X type) I setting

Cable Type and Maximum Length

Cable used Cat. 3, 5 straight UTP Cat. 3, 5 straight UTP Cat. 3, 5 straight UTP Cat. 3, 5 straight UTP Cat. 3, 5 straight UTP Cat. 5 straight UTP Cat. 5 straight UTP Cat. 5 straight UTP Cat. 5 straight UTP

Connection

UTP Cable Category

Maximum length

10BASE-T (10Mbps)

Cat. 3, 5

100 meters

100BASE-TX (100Mbps)

Cat. 5

100 meters

14

Page 19
Image 19
KTI Networks 2028 manual 10/100BASE-TX Switched Ports, Cable Type and Maximum Length