Image 26
INSPECTION AND ADJUSTMENTS
BEFORE S/N

3100ST 006046 010507

INSPECTION AND ADJUSTMENTS

IMPORTANT! Read before operating mixer.

It is the responsibility of the owner to make sure the mixer is set up properly.

The following recommendations should be helpful.

ELECTRONIC SCALES

Scale Indicator: Refer to the electronic scale operator’s manual for adjustment information. The operator’s manual for the Electronic Scales should be kept with this manual. Additional copies of scale manuals may be obtained through Kuhn Knight, Inc.

Load cells and weigh bars should be kept clean, dry and lubricated to ensure dependability.

3150 - 3195 AND

3136 BEFORE S/N B0001,

3142 BEFORE S/N B0001

Check arm assembly must be free to rotate slightly by hand when mixer is on level ground with mounting bolts tight.

3150 TO 3195 AND

3136 BEFORE S/N B0001,

3142 BEFORE S/N B0001

Vertical check bolts must not be tight and should be free to rotate by hand. There should be 1/16” to 3/32” free play when properly adjusted on level ground.

3136 B0001,

3142 BEFORE S/N B0001

PIN CHECK BEARING should be centered on the pin when mixer is on level ground. Adjustment can be made by loosening the mounting bolts, centering pin check assembly on the pin and tightening the mounting bolts. If bushing cannot be centered load cells may require adjustment.

NORMAL SCALE ACTIVITY

Some warm up scale drift may occur after the scale is turned on but should zero balance within 10 to 15 minutes. Scale may zero shift over night due to temperature changes.