Kuhn Rikon 3100 Trouble Shooting, Problem Oil Leaking Around The Edges Of The Oil Bath

Models: 3100

1 36
Download 36 pages 41.93 Kb
Page 34
Image 34
PROBLEM: OIL LEAKING AROUND THE EDGES OF THE OIL BATH

3100ST 006046 010507

TROUBLE SHOOTING

PROBLEM: OIL LEAKING AROUND THE EDGES OF THE OIL BATH

CAUSE

SOLUTION

 

 

INSPECT SHIELD FOR LOOSENESS

Check for foreign material between the foam gasket and shield.

 

Carefully tighten wing nuts or adjust locking fasteners that hold

 

shield in place; hand tighten only.

DAMAGED OR LOOSE GASKET MATERIAL AROUND

Remove shield and check gasket material for proper adhesion to

ENCLOSURE SHIELD

the mating panel of the mixer. If gasket adhesive has come

 

loose fro the front panel, replace the gasket.

PROBLEM: HYDRAULIC DOOR SYSTEM OPERATES ERRATICALLY

 

 

CAUSE

SOLUTION

 

 

COMPONENTS STICKING OR BINDING

Check for hydraulic oil for contamination, dirt, or gummy deposits;

 

find and repair the source of contamination. Check for worn or

 

bent parts and replace. Check oil level in hydraulic system.

INADEQUATE FLOW OR PRESSURE FROM HYDRAULIC SYSTEM.

Check fluid and fill to proper level.

OIL IS LEAKING PAST SEALS IN CYLINDERS OR VALVES

Install seal kits to repair worn seals. See Parts Manual for part

 

numbers.

 

 

PROBLEM: SCALE HANGS UP, LOAD CELL ONLY

 

 

 

CAUSE

SOLUTION

 

 

LOAD CELL NOT VERTICAL

With the mixer empty, adjust the load cell by loosening top load

 

cell mount, move the load cell to a vertical position and retighten

 

the load cell mount’s fasteners.

PIN CHECK OUT OF ADJUSTMENT

Remove pin check assembly, test scale, if scale operates

 

properly clean or repair pin check assembly. See INSPECTIONS

 

AND ADJUSTMENTS, ELECTRONIC SCALES section.

CHECK ARM NOT LUBRICATED

Lubricate check arm until it easily rotates on sockets.

 

See INSPECTIONS AND ADJUSTMENTS, ELECTRONIC

 

SCALES section.

 

 

PROBLEM: SCALE WEIGHS VERY HEAVY OR VERY LIGHT, WEIGH BAR ONLY

 

 

CAUSE

SOLUTION

 

 

IMPROPER CALIBRATION

Use the scale’s operator’s manual and re-calibrate the scale.

DAMAGED CABLE ON ONE OR MORE

Inspect cables and repair or replace as necessary.

LOAD CELLS OR WEIGH BARS

 

 

 