La Crosse Technology WS-7058U Temperature measuring range, Relative humidity range, Air pressure

Models: WS-7058U

1 24
Download 24 pages 52.75 Kb
Page 21
Image 21

Weather Center—recommended

32°F to 122°F (0°C to 50°C).

operating temperature:

 

LCD contrast:

8 levels (0-7).

Temperature measuring range

 

Indoor:

14°F to 140°F with 0.2°F resolution.

 

(-9.9°C to 59.9°C with 0.1°C resolution).

 

“OFL” displayed if outside this range).

 

 

Outdoor:

-22°F to 140°F with 0.2°F resolution.

 

(-29.9°C to 59.9°C with 0.1°C resolution).

 

“OFL” displayed if outside this range.

 

 

Relative humidity range

 

Indoor/Outdoor:

20% to 95% with 1% resolution. Display

 

“--.-” if outside this range.

 

 

Air pressure

 

Absolute hPa/inHg:

700 hPa to 1099 hPa.

 

(20.67 inHg to 32.46 inHg).

Relative hPa (adjustable):

970 hPa to 1030 hPa.

Relative inHg (adjustable):

28.60 inHg to 30.45 inHg.

Sensitivity setting hPa:

1 hPa to 4 hPa.

Air pressure history:

For the past484-hours (0, -1, -3, -6, -12,

 

-18, -24, -36, and –48).

 

 

Rainfall measurements

 

Rain quantity display:

0, 0.1, 0.3, 0.5, 1, 2, 3, 5, 10 inches or 0,

 

1, 3, 5, 10, 20, 30, 50, 100 inches—scale

 

change is automatic if rain greater than

 

7-8 inches (178-203mm). (0, 1, 3, 5, 10,

 

30, 50, 100 mm or 0, 10, 30, 50, 100, 300,

 

500, 1000 mm).

Rain quantity history:

For the past 7 days (0, -1, -2, -3, -4, -5, -6,

 

and –7).

 

 

Data checking intervals

 

Indoor temperature & humidity:

Every 10 seconds.

Outdoor temperature:

Every 10 seconds for the first 12 minutes,

 

then every 5 minutes.

Outdoor humidity:

Every 10 seconds for the first 12 minutes,

 

then every 5 minutes.

Rain quantity:

Every 10 seconds for the first 12 minutes,

 

then every 5 minutes.

Sensor reading update

 

 

21

Page 21
Image 21
La Crosse Technology WS-7058U Temperature measuring range, Relative humidity range, Air pressure, Rainfall measurements