C.HARD RESET OF EEPROM WEATHER CENTER MEMORY

Note: This is to be used if there are problems with transmission, or if the rainfall history bar graph needs to be cleared.

1.Remove the batteries and wait 30 seconds. (This will also reset the Rainfall Quantity Totals).

2.Checking the polarity, install batteries.

3.During the brief 2 seconds that all LCD screens light up, simultaneously press and hold the MOON and MIN/MAX buttons.

“267” (the default rain multiplicator setting) will appear in LCD 1. The “7” will be flashing.

If “267” does not appear, it will be necessary to set the manually set the digits. Use the CH/+ button to change the digit, and the SET button to select the digit to be changed.

4.Press the SET button two times. (The 2 should flash).

5.Hold the SET button down until the air pressure (in hPa) briefly flashes in LCD 4. “LCD 7” will flash in LCD 2 for 15 seconds.

6.Do not press any buttons while the Weather Center searches for transmission signals.

7.Follow Program Mode for set-up procedures.

VII. ADDING MORE SENSORS (optional)

The WS-7095U can receive signals from up to three Sensors. The Sensor model(s) that you choose will come with their own set of instructions—follow those instructions for a complete guide to setting up. Following are some brief instructions for the basic set-up of additional sensors with the WS-7095U. Additional sensors can be purchased through the same dealer as this Weather Center, or by contacting La Crosse Technology directly (contact information can be found at the end of this manual). A TX4U will monitor temperature and humidity (it is the same model that comes with the WS-7095U), a TX3U will monitor temperature only, and the TX3UP monitors temperature via a 10 foot probe for use in pools, spas, etc. The TX3 units do not monitor humidity, thus when they transmit their information to the Weather Center dashes “- -” appear in the Humidity Display.

Note: When setting up multiple sensors it is important to remove the batteries from all existing units in operation, then to insert batteries first into all the sensors, and in numeric sequence. Second install batteries into the Weather Center. Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6 min.