Langley/Empire DV-20E-5, DV-40E-5 Furnace Control Board Diagnostics, # of Blinks, Fault Condition

Models: DV-40E-5 DV-20E-5

1 20
Download 20 pages 11.69 Kb
Page 16
Image 16

FURNACE CONTROL BOARD

DIAGNOSTICS

FAULT SEQUENCE CODE — TROUBLE SHOOTING GUIDE

# of Blinks

Fault Condition

Fault Correction

Steady On

Control OK

 

1

Flash

Temperature limit switch is open

-Check Circulating Air Blower Inlet or Grill Outlet for Blockage, Inducer

 

 

 

Blower/Circulating Air Blower Run to Cool Heat Exchanger and Limit

 

 

 

-Check for Flame Roll Out Condition Causing Roll Out Limit Switch on

 

 

 

Burner Box to Open

 

 

 

-Clean Circulating Air Filter

2

Flashes

Pressure switch is open with inducer on

-Check Heat Exchanger and Flue System, Outlet and Inlet for Restriction

 

 

 

-Check Inducer Blower/Wheel for Operation/Airflow

 

 

 

-Check Pressure Switch

3

Flashes

Pressure switch is closed with inducer off

-Check Pressure Switch and Replace

4

Flashes

Lockout due to failed ignition

-Check for Broken Ignitor

 

 

 

-Check for Bent Ignitor Bracket - Ignitor too far from Burner

 

 

 

-Check for Flame Sensor Malfunction/or False Ground

 

 

 

-Check Gas Valve

 

 

 

-Reset Thermostat

5

flashes

L1/Neutral reversed or voltage not present

-Shut Off Power to Unit and Dis-Connect Cordset Plug from Wall Recep-

 

 

on L1

tacle.

 

 

 

Open Junction Box and Un-Reverse Polarity of Incoming Power Leads

Rapid Flash

Flame sense or internal control fault

-Check Ignitor Operation

 

 

 

-Check Flame Sensor for Malfunction or False Grounding

 

 

 

-Check Gas Valve

 

 

 

-Reset Thermostat

Note: If the hot surface ignitor is to be replaced, be sure to disconnect all power to the unit. Be very careful in handling the new ignitor as they are fragile and can be broken easily if hit or dropped.

Page 16

19562-1-0606

Page 16
Image 16
Langley/Empire DV-20E-5 Furnace Control Board Diagnostics, Fault Sequence Code- Trouble Shooting Guide, # of Blinks