7: Line and Tunnel Settings
PremierWave XC User Guide 51
To Configure Tunnel Packing Mode Settings
Using Web Manager
To configure the Packing Mode for a specific tunnel, click Tunnel in the menu bar and select
Tunnel 1 -> Packing Mode.
Using the CLI
To enter the Tunnel 1 Packing command level: enable -> tunnel 1 -> packing
Using XML
Include in your file: <configgroup name="tunnel packing" instance="1">
Accept Mode
In Accept Mode, the PremierWave XC listens (waits) for incoming connections from the network.
A remove node on the network initiates the connection.
The configurable local port is the port the remote device connects to for this connection. There is
no remote port or address. The default local port is 10001 for serial line 1 and 10 002 for serial
line 2.
Serial data can still be received while waiting for a network connection, k eeping in mind serial
data buffer limitations.
Table 7-5 Tunnel Accept Mode Settings
Tunnel Accept Mode
Settings Description
Mode Sets the method used to start a tunnel in Accept mode. Choices are:
Disable = do not accept an incoming connection.
Always = acc ept an incoming connection. (default)
Any Character = start waiting for an incoming connection when any character is
read on the serial line.
Start Character = start waiting for an incoming connection when the start
character for the selected tunnel is read on the serial line.
Modem Control Asserted = start waiting for an incoming connection as long as
the Modem Control pin (DSR) is asserted on the serial line until a connection is
made.
Modem Emulation = start waiting for an incoming connection when triggered by
modem emulation AT commands. Connect mode must also be set to Modem
Emulation.
Local Port Sets the port number for use as the network local port. The defaults are as follows:
Tunnel 1 : 10001
Tunnel 2 : 10002
Protocol Select the protocol type for use with Accept Mode:
SSH
SSL
TCP (default protocol)
TCP AES