7:Line and Tunnel Settings

Line Settings

Description

 

 

 

 

Baud Rate

Sets the Baud Rate (speed) of the Line. The default is 9600.

 

 

Any set speed between 300 and 921600 may be selected: 300, 600, 1200, 2400,

 

4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600.

When

 

selecting Custom baud rate (available for line 1 and line 2 only), you may manually

 

enter any value between 300 and 5000000.

 

 

 

 

Parity

Sets the Parity of the Line. The default is None.

 

 

 

 

Data Bits

Sets the number of data bits for the Line. The default is 8.

 

 

 

 

Stop Bits

Sets the number of stop bits for the Line. The default is 1.

 

 

 

 

Flow Control

Sets the flow control for the Line. The default is None.

 

 

 

Xon Char

Set Xon Char to be used when Flow Control is set to Software. Prefix decimal with \

 

or prefix hexadecimal with 0x or prefix a single control character <control>.

 

 

Xoff Char

Set Xoff Char to be used when Flow Control is set to Software. Prefix decimal with \

 

or prefix hexadecimal with 0x or prefix a single control character <control>.

 

 

Gap Timer

Set the Gap Timer delay to Set the number of milliseconds to pass from the last

 

character received before the driver forwards the received serial bytes. By default,

 

the delay is four character periods at the current baud rate (minimum 1 ms).

 

 

Threshold

Set the number of threshold bytes which need to be received in order for the driver to

 

forward received characters.

 

 

 

 

Command Mode

 

Table 7-2 Line Command Mode Settings

 

 

Line Command

Description

Mode Settings

 

 

 

Mode

Sets the Command Mode state of the Line. When in Command Mode, a CLI session

 

operates exclusively on the Line. Choices are:

 

Always

 

Use Serial String

 

Disabled

 

Note: In order to enable command mode on the Line, Tunneling on the Line must be

 

Disabled (both connect and accept modes).

 

 

Wait Time

Enter the amount of time to wait during boot time for the Serial String. This timer

 

starts right after the Signon Message has been set on the Serial Line and applies only

 

if mode is “Use Serial String”.

 

 

PremierWave XC User Guide

47

Page 47
Image 47
Lantronix 900-598 manual Command Mode, Line Command Description Mode Settings

900-598 specifications

The Lantronix 900-598 is a powerful and versatile device designed to facilitate robust data communication and management for industrial and commercial applications. At the heart of the 900-598 lies its advanced networking capabilities, making it an essential tool for IoT implementations, operational efficiency, and remote device management.

One of the main features of the Lantronix 900-598 is its ability to provide secure and reliable connectivity. The device supports various communication protocols, including serial and Ethernet, enabling seamless integration with a wide array of devices across diverse environments. This flexibility allows users to connect legacy equipment to modern networks, thereby extending the life of existing technologies while enhancing operational capabilities.

The Lantronix 900-598 is equipped with robust security measures to protect sensitive data during transmission. It supports encryption protocols, such as SSL and SSH, ensuring that data remains confidential and secure from unauthorized access. This security is crucial for industries dealing with sensitive information, such as healthcare, finance, and manufacturing, where data breaches can have severe repercussions.

Another notable characteristic of the 900-598 is its ease of use. The device features a user-friendly interface that simplifies setup and configuration. Additionally, it supports remote access and management, allowing users to monitor and control devices from virtually anywhere. This remote management capability is particularly advantageous for organizations with distributed operations, enabling them to maintain oversight without needing to be physically present at each location.

In terms of performance, the Lantronix 900-598 offers high-speed data transfer rates, which are essential for real-time applications. It is designed to handle large volumes of data efficiently, making it suitable for applications that require quick responses and minimal latency. The device ensures reliable operation through features like error correction and data integrity monitoring.

Lastly, the Lantronix 900-598 is built to withstand challenging environmental conditions, thanks to its rugged design. This durability makes it suitable for deployment in harsh industrial settings, where exposure to dust, moisture, and extreme temperatures is common.

In conclusion, the Lantronix 900-598 stands out as an advanced solution for data communication and device management. Its combination of secure connectivity, ease of use, high performance, and durability makes it an excellent choice for businesses looking to modernize their operations and embrace the future of IoT and remote management. With its extensive features and robust technologies, the 900-598 is poised to enhance productivity and streamline processes across various industries.