7:Line and Tunnel Settings
The PremierWave XC contains two Lines. Lines 1 and 2 are standard RS232/RS485 serial ports.
RS232/RS422/RS485
Lines 1 and 2 can be configured to operate in the following modes:
RS232
RS422/RS485 Full Duplex
RS422/RS485 Half Duplex, with and without termination impedance
All serial settings such as Baud Rate, Parity, Data Bits, etc, apply to these Lines.
Line Settings
The Line Settings allow configuration of the serial Lines (ports). Some settings may be specific to only certain Lines. Such settings are noted below.
Configuration
| Table |
|
|
Line Settings | Description |
|
|
Name | Enter a name or short description for the line, if desired. By default, there is no name |
| specified. A name that contains white space must be quoted. |
|
|
Interface | Sets the interface type for the Line. The default is RS232 for Lines 1 and 2. |
| Choices are: |
| RS232 (Lines 1 and 2 only) |
| RS485 |
| RS485 |
|
|
Termination | Sets the Line Termination to Enabled or Disabled. The default is Disable. |
| Note: This setting is only relevant for Lines 1 and 2 with Interface type RS485 Half- |
| Duplex. |
|
|
State | Sets the operational state of the Line to either Enable or Disable. The default is |
| Enable. |
|
|
Protocol | Sets the operational protocol for the Line. The default is Tunnel. Choices are: |
| None |
| Tunnel = |
|
|
PremierWave XC User Guide | 46 |