Lantronix 900-598 manual Line and Tunnel Settings, RS232/RS422/RS485, Line Settings, Configuration

Models: 900-598

1 109
Download 109 pages 26.19 Kb
Page 46
Image 46

7:Line and Tunnel Settings

The PremierWave XC contains two Lines. Lines 1 and 2 are standard RS232/RS485 serial ports.

RS232/RS422/RS485

Lines 1 and 2 can be configured to operate in the following modes:

RS232

RS422/RS485 Full Duplex

RS422/RS485 Half Duplex, with and without termination impedance

All serial settings such as Baud Rate, Parity, Data Bits, etc, apply to these Lines.

Line Settings

The Line Settings allow configuration of the serial Lines (ports). Some settings may be specific to only certain Lines. Such settings are noted below.

Configuration

 

Table 7-1 Line Configuration Settings

 

 

Line Settings

Description

 

 

Name

Enter a name or short description for the line, if desired. By default, there is no name

 

specified. A name that contains white space must be quoted.

 

 

Interface

Sets the interface type for the Line. The default is RS232 for Lines 1 and 2.

 

Choices are:

 

RS232 (Lines 1 and 2 only)

 

RS485 Full-Duplex(Lines 1 and 2 only)

 

RS485 Half-Duplex(Lines 1 and 2 only)

 

 

Termination

Sets the Line Termination to Enabled or Disabled. The default is Disable.

 

Note: This setting is only relevant for Lines 1 and 2 with Interface type RS485 Half-

 

Duplex.

 

 

State

Sets the operational state of the Line to either Enable or Disable. The default is

 

Enable.

 

 

Protocol

Sets the operational protocol for the Line. The default is Tunnel. Choices are:

 

None

 

Tunnel = Serial-Network tunneling protocol.

 

 

PremierWave XC User Guide

46

Page 46
Image 46