4: Configuration Using Web Manager 
UDS2100 unit automatically. Enable is the default. 
AutoIP  Select Enable to permit the UDS2100 to generate an IP in the 
169.254.x.x address range with a Class B subnet. Enable is 
the default. 
DHCP Host Name  Enter the name of the host on the network providing the IP 
address. 
Note: Disabling BOOTP, DHCP, and AutoIP (all three checkboxes) is not 
advised as the only available IP assignment method will then be ARP or 
serial port. 
4.  When you are finished, click the OK button. 
5.  On the main menu, click Apply Settings. 
Static IP Address Configuration You can manually assign an IP address to the unit and enter related network 
settings. 
To assign an IP address manually: 
1.  On the main menu, click Network. 
2. Select Use the following IP configuration. 
3.  Enter the following (as necessary): 
IP Address  If DHCP is not used to assign IP addresses, enter it manually 
in decimal-dot notation. The IP address must be set to a 
unique value in the network.  
Subnet Mask  A subnet mask defines the number of bits taken from the IP 
address that are assigned for the host part. 
Default Gateway  The gateway address, or router, allows communication to 
other LAN segments. The gateway address should be the IP 
address of the router connected to the same LAN segment as 
the unit. The gateway address must be within the local 
network.  
DNS Server  The DNS server allows the name of a remote machine to be 
resolved automatically. Enter the IP address of the DNS 
server. If the device is DHCP enabled, the DHCP server 
provides the DNS server IP address, which will override this 
configured value. 
Note: This setting is applicable only in Manual Connection 
mode. 
4.  When you are finished, click the OK button. 
5.  On the main menu, click Apply Settings. 
Ethernet Configuration You must specify the speed and direction of data transmission. 
To specify how data will be transmitted: 