7: Setup Mode: Channel Configuration 
Message   Meaning  
RING n.n.n.n.  A remote device, having IP address n.n.n.n, is connecting to this 
device. 
Numeric Response 
0 OK 
1 Connected 
2 Ring 
3 No Carrier 
4 Error 
Received commands must begin with the two-character sequence AT and be 
terminated with a carriage return character. 
The unit ignores any character sequence received not starting with AT, and only 
recognizes and processes single AT-style commands. The unit treats compound AT 
commands as unrecognized commands.  
If the Full Verbose option is in effect, the unit responds to an unrecognized 
command string that is otherwise formatted correctly (begins with AT and ends with 
carriage return) with the "OK" message and takes no further action. 
If the Numeric Response option is in effect, the unit responds to an unrecognized 
command string that is otherwise formatted correctly with a "0" message and takes 
no further action. 
When an active connection is in effect, the unit transfers data and does not process 
commands received from the serial interface. 
When a connection is terminated or lost, the unit reverts to command mode. 
When an active connection is in effect, the unit terminates the connection if it 
receives the following sequence from the attached serial device: 
 No serial data is received for one second. 
 The character sequence +++ is received, with no more than one second 
between each two characters. 
 No serial data is received for one second after the last + character. At this time, 
the unit responds affirmatively per the selected echo/response mode. 
 The character string ATH is received terminated with a carriage return. The 
unit responds affirmatively according to the selected echo/response mode and 
drops the network connection. The serial interface reverts to accepting 
command strings. 
If this sequence is not followed, the unit remains in data transfer mode. 
Table 7-6. Modem Mode Commands 
Modem Mode 
Command   Function  
ATDTx.x.x.x,pppp or 
ATDTx.x.x.x/pppp 
 or 
Makes a connection to an IP address (x.x.x.x) and a remote port 
number (pppp).  
 UDS2100 User Guide   50