4: Configuration Using Web Manager sequence). 
Connect Mode: Active Connection Active Connect  Select None (default) to disable Active Connect. Otherwise, 
indicate the connection type from the drop-down list: 
 With Any Character: Attempts to connect when any 
character is received from the serial port. 
 With Active Mdm Ctrl In: Accepts external 
connection requests only when the Modem Control 
In input is asserted. 
 With Start Character: Attempts to connect when it 
receives a specific start character from the serial 
port. The default start character is carriage return. 
 Manual Connection: Attempts to connect when 
directed by a command string received from the 
serial port.  
 Auto Start: Automatically connects to the remote IP 
address and port after booting up. 
Start Character  If Active Connect is set to With Start Character, enter the start 
character in this field. The default setting is 0D. 
Modem Mode  Indicates the on-screen response type when in Modem Mode 
(if Modem Mode is enabled). The default setting is None. 
Show IP Address After 
Ring 
Indicates whether to display the remote IP address upon 
connection. The default setting is Yes. 
Endpoint Configuration Local Port  Enter the local port number. 
Auto increment for active 
connect 
Select to auto-increment the local port number for new 
outgoing connections. The range of auto-incremented port 
numbers is 50,000 to 59,999 and loops back to the beginning 
when the maximum range is reached. Disabled by default. 
Remote Port  Enter the remote port number. 
Remote Host  Enter the IP address of the re mote device. 
Common Options Telnet Com Port Cntrl  Available for configuration only when Active Connect is set to 
None. Select Enable to permit Telnet communication to the 
UDS unit. The Telnet Com Port Cntrl feature is used in 
conjunction with the Com Port Redirector (CPR) utility. (See 
the CPR online Help for details.) 
Connect Response  A single character is transmitted to the serial port when there 
is a change in connection state. Default setting is None. 
Terminal Name  Available for configuration only when Telnet Com Port Cntrl 
is set to Enable. 
Use the terminal name for the Telnet terminal type. Enter only 
 UDS2100 User Guide   32