Gas
Valve
Control
Hinge PinCompartment
Millivolt Appliances -
To light millivolt appliances refer to the detailed lighting instructions found on page 11 (English) and page 12 (French). Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
Millivolt appliances are fitted with an ON/OFF Rocker Switch for appliance ON/OFF control. See Figure 1 for its location. Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate:
If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.
Manifold Pressure Port | ON/OFF Switch |
| ||
CONTROL | OFF ON | IN | Inlet | |
Pressure | ||||
REITNIG |
|
| ||
|
| Port | ||
|
|
| ||
|
| IPS |
|
ON/OFF Switch
Access Panel
Toggle the switch between its ON and OFF positions.
Electronic |
Gas Control |
Valve |
Piezo Ignitor Modesty Panel
Control Compartment Access -
Millivolt Control Valve Shown
Figure 1
Remove the bottom compartment door by sliding the hinge pin, located at the door’s left side, to the right until it disengages from the left corner post hole. Pull the door diagonally to the left, away from the fireplace.
Once the control compartment door has been removed, the modesty panel can be removed as follows: slide the modesty panel forward until it contacts the cabinet bottom panel, then lift straight up and tilt forward. Remove the modesty panel carefully, so that none of the wires become loose or disconnected. Now complete access to the gas control valve and its related controls is attainable.
To ease door closure, depress the catches to place them in their retracted position until they stay there, then close the door.
If your millivolt appliance is equipped with an optional remote wall switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control.
Electronic Appliances -
To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 13 and 14 of these instructions respectively. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Electronic appliances are fitted with an ON/ OFF Rocker Switch for appliance ON/OFF control. See Figure 1 for its location.
Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF op- eration. To operate: Toggle the switch between its ON and OFF positions.
| Honeywell Electronic |
Figure 3 | Gas Valve |
Variable Flame Height Adjustment ( Millivolt Appliances only)
1.All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alter- nately, while the appliance is in operation.
Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob located on the front of the valve (refer to Figure 2). (An extension is provided to this knob so that the adjustment may be made at the modesty panel.)
2.When lit for the first time, this appliance will emit a slight odor for an hour or two. This is due to the
lubricants used in the manufacturing process.
Operation of millivolt and electronic gas control systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance.
Refer to Figure 1 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 2.
Appliances with electronic systems will be fitted with the electronic valve shown in Figure 3. Familiarize yourself with the gas control valve that your appliance uses.
4
Variable Flame Height Adjustment | Inlet Pressure Port | ||||
| Manifold Pressure Port |
| |||
|
|
| OUT | IN |
|
TPTH |
|
|
|
|
|
TP |
| I H |
|
|
|
|
|
| OFF | P |
|
|
|
|
|
| |
|
|
|
| I |
|
|
| LO W | it | L |
|
TH |
| O |
| ||
|
|
| NO | T |
|
|
|
|
|
| |
|
| P |
|
|
|
| I |
|
|
| |
| TOL |
|
|
|
|
|
|
|
|
| Main Gas |
| SIT Millivolt Gas Valve | Control Knob |
Note: The piezo ignitor is located on the modesty panel - refer to Figure 1.
Figure 2