Burner Air Shutter Adjustment Procedure
CAUTION
The air shutter door and nearby appliance surfaces are hot. Exercise caution to avoid injury while adjusting flame appearance.
Burner Air Shutter Adjustment Procedure
1. Locate adjustment rod and adjust air shutter to the standard setting as shown in Figure 60 (adjustment rod is located in the lower control compartment).
Note: Move the adjustment rod down to decreases air and up to increases.
2.Light appliance (follow lighting procedure on lighting label in control compartment or see homeowners manual).
3.Allow the burner to operate for at least 15 minutes while observing the flame continuously to ensure that the proper flame appearance has been achieved (see Figures57 or 58). If the following conditions are present, adjust accordingly.
•If flame appears weak or sooty, adjust the air shutter, incremen- tally, to a more open position until the proper flame appearance is achieved.
•If flame stays lowered blue, adjust the air shutter, incrementally, to a more closed position until the proper flame appearance is achieved.
Figure 58- Burner Flame Appearance Model
Figure 59 - Burner Flame Appearance Model
4.Leave the control knob (off/pilot/on) in the ON position and the burner OFF/ON switch OFF (& remote switches, if applicable).
5.When satisfied that the burner flame appearance is normal,
Adjustment
| Adjustment | |
| Rod Up | |
Burner | (Fully Open | |
Position) | ||
Tube | ||
| ||
Air Shutter |
| |
Adjustment Rod Down min. | Ref. Air shutter Patent: | |
air opening position) | U.S. Pat. 5,553,603 |
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model | Nat.Gas | Propane Gas |
|
|
|
1/16 (1.58) | 1/4" (6.35) | |
|
|
|
1/16 (1.58) | 1/4" (6.35) | |
|
|
|
1/16(1.58) | 5/16" (7.94) | |
|
|
|
1/8 (3.18) | 3/8" (9.53) | |
|
|
|
Figure 60 - Burner Air Shutter Adjustment
Step 11. Hood Installation
(Refer to Figure 61) All of these appliances must have hoods installed prior to operating.
Install hood by sliding it into the slots on the lower edge of the cabinet top.
Finishing Requirements - Wall Details
Complete finished interior wall. To install the appliance facing flush with the finished wall, position framework to accommodate the thickness of the finished wall (Figure 61 ).
See Page 4 for Cold Climate Insulation
and Page 7 for Clearances
| This Area Must | 3" |
| Remain Clear of | |
| (76 mm) | |
| Combustible | |
| Materials |
|
Combustible Finished | 1 in. Min. |
|
Wall Materials |
| |
| (25 mm) |
|
| Top Spacers |
|
Drywall Bracket / Spacer
Combustible material may touch the appliance top
Top of Appliance Louvers
Top of Door Frame
Hood must be installed as shown.
Figure 61 - Combustible Wall Framing
30