Lennox Hearth LSBV-3628MN-H, LSBV-4228MP Appliance Specifications, Clearances, Venting

Models: LSBV-3628MP-H LSBV-4228EN-H LSBV-3628MN-H LSBV-3628MN LSBV-4228EN LSBV-4228MN-H LSBV-4228MP LSBV-3628EN LSBV-3628MP LSBV-4228MN LSBV-4228MP-H LSBV-3628EN-H

1 16
Download 16 pages 14.71 Kb
Page 4
Image 4
APPLIANCE SPECIFICATIONS

APPLIANCE SPECIFICATIONS

 

12-15/32

7-3/32

 

 

52-11/32

 

47-9/32

28-15/32

41-5/16

 

5-3/4

LSBV-36: 37

 

LSBV-42: 43

 

LSBV-36: 41-3/4

 

LSBV-42: 47-3/4

Front View

The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materi- als. However, if installed on combustible mate- rials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom surface must be used.

These appliances may be used for bedroom installations in the United States and are listed accordingly. These units may not be installed in bedrooms in Canada.

CLEARANCES

Minimum clearance to combustibles for the ap- pliance is as follows: sides and back - 3/8" (9.52 mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm), ceiling - 37-1/2" (953 mm).

Venting

Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.4 mm) of a vertical wall or similar obstruction. Gas vent caps that are located 8' or more from a portion of a building which extends at an angle greater than 45° upward from the horizontal may terminate in accordance with Table 1 (Figure 3), provided that in no case shall any discharge opening on the cap be less than 2' (610 mm) horizontally from the roof surface (National Fuel Gas Code ANSI Z223.1 (NFPA 54) 7.6.2) (CAN/CGA B149).

Gas Line

Or Switch

Wire Outlet

8-7/8

Combustion

Air Inlet

 

7-7/16

 

 

 

 

 

Junction

 

 

 

Box

 

15-27/32

Gas Line

Location

 

Or Switch

 

1-7/16

1-25/32

Wire Outlet

 

 

 

4-13/32

2-9/32

CLEARANCES 16-1/16 Venting

X

12

Roof Pitch is X/12

Minimum Height from Roof to Lowest Discharge Opening

Figure 3

Minimum Height

from Roof to Lowest

4

Left Side View

Right Side View

LSBV-36: 23-1/2

LSBV-42: 29-1/2

8-15/32

20-1/32

19/32

Top View

Figure 2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Roof Slope

Discharge Opening

 

 

 

 

Feet

Meters

Flat to 6/12

1' 0"

0.3

Over 7/12 to 9/12

2' 0"

0.6

Over 10/12 to 12/12

4' 0"

1.2

Over 13/12 to 16/12

6' 0"

1.8

 

 

 

Over 17/12 to 21/12

8' 0"

2.4

 

 

 

Note: Venting terminals shall not be recessed into a wall or siding.

Table 1

Page 4
Image 4