Lennox Hearth LSBV-4228MN-H Packaging, Introduction, General Information, Orifice Size, Type

Models: LSBV-3628MP-H LSBV-4228EN-H LSBV-3628MN-H LSBV-3628MN LSBV-4228EN LSBV-4228MN-H LSBV-4228MP LSBV-3628EN LSBV-3628MP LSBV-4228MN LSBV-4228MP-H LSBV-3628EN-H

1 16
Download 16 pages 14.71 Kb
Page 2
Image 2
PACKAGING

2

TABLE OF CONTENTS

 

 

Packaging

page

2

Introduction

page

2

Massachusetts and New York

 

 

Requirements

page

2

General Information

page

2

Location

page

3

Appliance Specifications

page

4

Clearances

page

4

Gas Vent Rule

page

4

Framing Specifications

page

5

Assembly Steps

page

5

Installation

page

6

Vent System Installation

page

7

Field Wiring

page

7

Connecting Gas Line

page

8

Outside Air Kit Installation

page

8

Log and Rockwool Installation

page

9

Appliance Operation

page

10

Manual Limit Switch

page

10

Millivolt Appliance Checkout

page

11

Electronic Appliance Checkout

page

11

Adjustments

page

11

Finishing Requirements

page

12

Cold Climate Insulation

page

12

Installation Accessories

page

12

Gas Conversion Kits

page 14

This manual is part of a set of two supporting this product. Refer to manual 875,035M for Care & Operations.

Please read and understand these instructions before beginning your installation.

PACKAGING

The assembled vented gas fireplace is pack- aged with:

1 - one foam packaged log set located in fire- box area.

2 - one bag of glowing embers (rockwool) located in the bottom compartment.

3 - one envelope containing the literature package which consists of the homeowner's manual, installation instructions, and war- ranty; envelope is located in the control area.

INTRODUCTION

The millivolt appliances are designed to oper- ate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation.

The electronic appliances are designed to op- erate on either natural or propane gas. An electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.

These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No. 116-F-45-5) to ANSI Z21.50b (in Canada, CSA-2.22b), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.

Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Elec- trical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)

These Crestline series appliances have been designed, tested and listed for use with Security Chimney's 10" B-vent system. Refer to page 12 for a complete listing of the 10" B-vent compo- nents available for use with these models.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDI- TIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

Massachusetts And New York City, NY Requirements

These appliances are approved for installation in the following USA locations listed in the following:

Massachusetts:

Installation of these fireplaces are approved for installation in the US state of Massachu- setts if the following additional requirements are met-

Installation and repair must be done by a plumber or gas fitter licensed in the Common- wealth of Massachusetts.

The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.

The individual manual shut-off must be a T- handle type valve.

New York City, NY:

Installation of these fireplaces are approved for installation in New York City in the US state of New York, if the following additional re- quirements are met-

An outside air kit (FOAK-4 or FOAK-4LD) must be installed.

GENERAL INFORMATION

Note: Installation and repair should be per- formed by a qualified service person. The appli- ance should be inspected annually by a quali- fied professional service technician. More fre- quent inspections and cleanings may be re- quired due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instruc- tions d'installation et d'utilisation qui accompagnent l'apareil.

Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLIANCES. DO NOT BURN WOOD OR OTHER MATE- RIAL IN THESE APPLIANCES.

These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the perfor- mance of this system and may be dangerous.

Input of appliance are 45,000 BTU/HR for Pro- pane models and 50,00 BTU/HR for Natural Gas models.

Gas

Orifice Size

 

Type

Natural

Propane

Elevation

LSBV-3628

#26

#45

0 - 4500'

(0 - 1370 m)

 

 

 

 

 

 

 

LSBV-4228

#26

#45

0 - 4500'

(0 - 1370 m)

 

 

 

 

 

 

 