LENNOX HEARTH PRODUCTS • MONTEBELLO® SEE-THROUGH POWER VENT DV GAS FIREPLACES (LSM40ST-N-PV) • CARE AND OPERATION INSTRUCTIONS

Troubleshooting GUIDE: ELECTRONIC GAS CONTROL SYSTEM

Note: Before troubleshooting the gas control system, make sure the external gas shutoff valve (located at gas supply inlet) is in the “ON” position.

Important: Valve system troubleshooting should only be performed by a qualified service technician.

 

Symptom

Possible causes

Corrective action

1.

Nothing happens when fireplace

A. Remote Control is not functioning

• Check that wall switchplate is set to REMOTE

 

is turned On/Off (pilot does not

properly.

(if remote was used).

 

spark).

 

• Operate fireplace from wall switchplate.

 

 

 

• Replace batteries in Remote Control and/or Receiver.

 

 

 

 

 

 

B. Gas is not reaching fireplace.

• Check gas supply and gas shutoff valves.

 

 

 

 

 

 

C. Unit is not receiving power.

• Check building circuit breakers to ensure power

 

 

 

is on to fireplace.

 

 

 

 

 

 

D. Damaged igniter wire.

• Check for visible cracked casing, cuts, etc.

 

 

 

 

 

 

E. Damaged pilot assembly.

• Check pilot assembly for visibly broken spark electrode, etc.

 

 

 

 

 

 

F. Batteries low.

• Check voltage on D.C. terminal of batteries in Remote Control.

 

 

 

The value should be around 3.0V.

 

 

 

 

2.

Igniter is sparking, but main

A. Gas is not reaching fireplace.

• Check gas supply and gas shutoff valves (call a service

 

burner does not light.

 

technician, if required).

 

 

 

 

 

 

B. Air in gas line.

• Call a service technician.

 

 

 

 

 

 

C. Loose wires to valve.

• Check control compartment for any obvious loose wiring

 

 

 

(call a service technician, if required).

 

 

 

• Ensure blue and white (2) wires are securely connected to

 

 

 

valve (call a service technician, if required).

 

 

 

 

 

 

D. Loose wires to ignition module.

• Check control compartment for any obvious loose wiring

 

 

 

(call a service technician, if required).

 

 

 

 

 

 

E. Loose sensor wire.

• Ensure sensor wire connection is secure to purple wire of

 

 

 

ignition control (call a service technician, if required).

 

 

 

 

 

 

F. Low voltage.

• Test voltage at AC terminals of module for 24 VAC. If no volt-

 

 

 

age, replace module (call a service technician, if required).

 

 

 

• Check electrical connections between module and gas control.

 

 

 

If okay, replace gas control (valve) (call a service technician,

 

 

 

if required).

 

 

 

 

3.

Main burner comes on,

A. Gas is not reaching fireplace.

• Check gas supply and gas shutoff valves.

 

but then goes out.

 

 

 

B. Loose wires to valve or ignition

• Check control compartment for any obvious loose wiring

 

 

 

 

module.

(call a service technician, if required).

 

 

 

 

 

 

C. Pilot flame is not engulfing sensor.

• Call a service technician.

 

 

 

 

 

 

D. Obstructed vent system.

• Call a service technician.

 

 

 

 

4.

Soot is present on logs and

A. Excessive flame impingement on logs.

• Check for proper placement of logs, volcanic stone, and

 

glass.

 

ember material.

 

 

 

 

 

 

B. Improper air shutter opening.

• Check for proper air shutter adjustment (call a service

 

 

 

technician, if required).

 

 

 

 

23

Page 23
Image 23