WHITE RODGERS 36E SERIES GAS VALVE

 

HIGH FIRE

 

MANIFOLD

 

PRESSURE

 

ADJUSTMENT

 

ON SIDE

 

(under cap)

 

MANIFOLD

 

PRESSURE

 

TAP ON SIDE

INLET PRESSURE

LOW FIRE MANIFOLD

TAP ON SIDE

PRESSURE ADJUSTMENT

 

ON SIDE (under cap)

GAS VALVE SHOWN IN OFF POSITION

 

FIGURE 36

8 −

Honeywell VR8205 Gas Valve − Turn knob on gas

 

valve counterclockwise

to ON. Do not force.

 

White Rodgers 36E Gas Valve − Switch gas valve lever

 

to ON. See figure 36 for the White Rodgers 36E

 

valve.

 

9 −

Replace the upper access panel.

10−

Turn on all electrical power to to the unit.

11− Set the thermostat to desired setting.

NOTE − When unit is initially started, steps 1 through 11 may need to be repeated to purge air from gas line.

12−

If the appliance will not operate, follow the instructions

 

urning Off Gas to Unit" and call your service techni-

 

cian or gas supplier.

 

Turning Off Gas to Unit

 

1 −

Set the thermostat to the lowest setting.

2 −

Turn off all electrical power to the unit if service is to be

 

performed.

 

3 −

Remove the upper access panel.

4 −

Honeywell VR8205 Gas Valve − Turn knob on gas

 

valve clockwise

to OFF. Do not force.

 

White Rodgers 36E Gas Valve − Switch gas valve le-

 

ver to OFF.

 

5 −

Replace the upper access panel.

C−Safety or Emergency Shutdown

Turn off unit power. Close manual and main gas valves.

D−Extended Period Shutdown

Turn off thermostat or set to mode. Close

all gas valves (both internal and external to unit) to guaran- tee no gas leak into combustion chamber. Turn off power to unit. All access panels and covers must be in place and se- cured.

IV−HEATING SYSTEM SERVICE CHECKS A−C.S.A. Certification

All units are C.S.A. (formally A.G.A. and C.G.A. combined) design certified without modifications. Refer to the G61MP Installation Instruction.

B−Gas Piping

CAUTION

If a flexible gas connector is required or allowed by the authority that has jurisdiction, black iron pipe shall be installed at the gas valve and extend outside the furnace cabinet.

WARNING

Do not exceed 600 in−lbs (50 ft−lbs) torque when attaching the gas piping to the gas valve.

Gas supply piping should not allow more than 0.5"W.C. drop in pressure between gas meter and unit. Supply gas pipe must not be smaller than unit gas connection.

Compounds used on gas piping threaded joints should be resistant to action of liquefied petroleum gases.

C−Testing Gas Piping

IMPORTANT

In case emergency shutdown is required, turn off the main shut-off valve and disconnect the main power to unit. These controls should be properly labeled by the installer.

When pressure testing gas lines, the gas valve must be dis- connected and isolated. Gas valves can be damaged if subjected to more than 0.5psig (14" W.C.). See figure 37.

GAS PIPING TEST PROCEDURE

MANUAL MAIN SHUT−OFF VALVE

CAP

GAS VALVE

FIGURE 37

Page 31

Page 31
Image 31
Lennox International Inc G61MP Safety or Emergency Shutdown, Extended Period Shutdown, Testing Gas Piping