Lennox International Inc Dave Lennox Signature Collection XC21 System installation instructions

Models: Dave Lennox Signature Collection XC21 System XC21

1 19
Download 19 pages 52.21 Kb
Page 1
Image 1
General

E2012 Lennox Industries Inc.

Dallas, Texas, USA

THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE

INSTALLATIONWARNING

The State of California has determined that this product may contain or produce a chemical or chemicals, in very low doses, which may cause serious illness or death. It may also cause cancer, birth defects, or reproductive harm.

General

This XC21 outdoor unit is designed for use with HFC−410A refrigerant only. This unit must be installed with an ap- proved indoor unit. See the Lennox XC21 Product Specifi- cations bulletin (EHB) for approved indoor component match ups.

These instructions are intended as a general guide and do not supersede local codes in any way. Consult authorities having jurisdiction before installation.

INSTALLATION

INSTRUCTIONS

Dave Lennox Signature® Collection XC21 System

AIR CONDITIONERS

 

506923−01

 

7/2012

Litho U.S.A.

Supersedes 4/2012

 

Dave Lennox Signature® Collection XC21 SystemWARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal inju- ry or loss of life.

Installation and service must be performed by a licensed professional installer (or equivalent) or service agency.

NOTICE !CAUTION

Before attempting to perform any service or mainte- nance, turn the electrical power to unit OFF at discon- nect switch.

NOTICE !

For more in−depth information, consult the Installa- tion and Service Procedures manual, available as Corp.1007−L2 on DaveNet or through the Technical Support department at 800−453−6669.

STEP 1 −− SETTING THE UNIT −− Clearances

CLEARANCE ON ALL SIDES

6 (152)

CONTROL

PANEL ACCESS

NOTES:

S

Clearance to access panel must be 30

 

inches (762mm).

S

Clearance to one of the other three

MINIMUM CLEARANCE

ABOVE UNIT

48 (1219)

12 (305)

LOCATION 30 (762)

sides must be 36 inches (914mm).

S Clearance to one of the remaining two

sides may be 12 inches (305mm) and

the final side may be 6 inches

(152mm).

36 (914)

MINIMUM CLEARANCE BETWEEN TWO UNITS

ACCESS PANEL

24

(610)

LINE SET CONNECTIONS

 

 

REAR VIEW OF UNIT

 

FIGURE 1

 

7/2012

Page 1

506923−01

*2P72012*

*P506923-01*

 

Page 1
Image 1