Lenovo 8094, 8089 XXX Press F3 to review the log file, XXX Make sure the component that is called

Models: 8089 8086 8087 8090 8094 8088

1 164
Download 164 pages 27.39 Kb
Page 72
Image 72

Diagnostic Error Code

FRU/Action

 

 

011-195-XXX

Information only

Serial port Test aborted by user

Re-start the test, if necessary

 

 

 

011-196-XXX

1.

Press F3 to review the log file

Serial port test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

011-197-XXX

1.

Make sure the component that is called

Serial port test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 53

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

011-198-XXX

1.

If a component is called out, make sure

Serial port test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 53

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 150

 

3.

Go to “Undetermined problems” on page

 

 

88

 

 

 

011-199-XXX

1.

Go to “Undetermined problems” on page

Serial port test failed, cause unknown

 

88

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 150

 

3.

Replace component under function test

 

 

 

011-2XX-XXX

1.

External serial device

Serial port signal failure

2.

System board

 

 

 

014-000-XXX

No action

Parallel port Interface Test Passed

 

 

 

 

 

014-001-XXX

1.

Remove external parallel device, if

Parallel port Presence

 

present

 

 

 

2.

Run setup, enable port

 

3.

System board

 

 

014-002-XXX

System board

014-003-XXX

 

 

Parallel port Timeout/Parity error

 

 

 

 

014-013-XXX

System board

014-014-XXX

 

 

Parallel port Control Signal/Loopback test

 

 

failure

 

 

 

 

 

014-015-XXX

1.

Wrap plug

Parallel port External Loopback failure

2.

System board

 

 

 

 

014-027-XXX

1.

Run Setup, enable port

Parallel port Configuration/Setup error

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 150

 

3.

System board

 

 

 

66Hardware Maintenance Manual

Page 72
Image 72