Lenoxx Electronics L30 BF-2 Maintenance, Log Set, Cleaning Burner, Cleaning Valve / Air Venturi

Models: L30 BF-2

1 25
Download 25 pages 53.41 Kb
Page 16
Image 16
MAINTENANCE

MAINTENANCE

Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be Performed By A Qualified Service Technician:

LOG SET

Removing & Cleaning Logs - Carefully remove the logs (removing top logs, then lifting front log out, then rear log). Use care when handling the fiber logs, as they be- come quite fragile after curing. Use a small soft-bristled brush (e.g., a nylon paint brush) to remove soot, dust or debris that may have accumulated on the burner or log set. Remove the logs and burner, and clean them out- side the home in a location with plenty of fresh air venti- lation. Avoid breathing fine particulates of dust that may be generated. See page 10, Installing Log Set for in- structions on reinstalling logs.

Replacing Logs - If logs become damaged by accident or improper handling and need replacement, use only the proper replacement logs from manufacturer, which can be purchased from your local dealer. See page 20.

CLEANING BURNER

With the logs removed, vacuum out any foreign matter (lint, carbon etc.) on the burner. Be sure the burner ports are “open.”

CLEANING VALVE / AIR VENTURI

Clean all lint and dust build-up around the control valve and air shutter on the venturi. Inspect and clean with a brush or wire the inlet of the venturi for any spider webs or lint accumulation.

INSPECT WIRING / CAUTIONS:

1)Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan- gerous operation.

2)Verify proper operation after servicing.

3)Inspect and clean all wire connections. Ensure that there is no melting or damage from rodents. Inspec- tion should include:

Terminals at the valve

On / Off switch

Wall Thermostat / Remote Control (optional kits)

VENTING SYSTEM

A periodic examination of the venting system must be performed to ensure that the flow of combustion air is not obstructed. We recommend that you have your gas ap- pliance checked yearly by your independent Lennox dealer.

CLEAN EXTERNAL SURFACES

External surfaces should be kept clean and dust re- moved form air inlets to the appliance. The flow of com- bustion and ventilation air must not be obstructed. The appliance must be kept clear and free from combustible materials, gasoline and other flammable vapors and liq- uids.

SMALL AREA PAINT TOUCH-UP

The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-C Stove Paint, Cata- log # 19L92. Do not touch-up this appliance with any other paint.

Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the touch between the painted and bare sur- faces. Do not let the sand paper gum up with paint, as this will cause scratches on the metal surface. If there are any scratches, use 600 grit sandpaper instead. Mask off surfaces you do not want painted. Paint lightly over the bare surface first as this will act as an undercoat. Then paint over a larger area in smooth even strokes to blend.

See Break-In Period on page 13 for information on curing the paint.

CLEANING GLASS

The window on the gas appliance is made from a clear ceramic material and may be cleaned when cool with any non-abrasive product designed for use on glass win- dows. Do not use abrasive cleaners on glass. The viewing glass should be cleaned periodically. Exterior glass may be cleaned with a glass cleaner as desired. Interior glass - use soap and water, or commercial glass cleaner recommended for stove glass.

Note: Each time the appliance is lit, it may cause con- densation and fog on the glass. This condensation and fog will disappear in a few minutes.

CLEANING BLOWER INTAKE

The blower air intake requires cleaning at least once a year to remove lint, dust, etc. If there are pets in the dwelling, the intake should be cleaned at least twice a year.

PAGE 16

Page 16
Image 16
Lenoxx Electronics L30 BF-2 Maintenance, Log Set, Cleaning Burner, Cleaning Valve / Air Venturi, Inspect Wiring / Cautions