PROPANE CONVERSION
7.High / Low Pressure Regulator Installation Proce- dure:
a.Remove regulator cap and conversion screw (see following illustration).
b.Install the new conversion screw (Red = Propane LP gas, Blue = Natural Gas). Ensure that the con- version screw is finger tight. Install the new regu- lator cap.
c.Affix conversion label on gas control valve body where it can easily be seen.
8.Reinstall burner cover, logs, ember wool / ceramic rocks and glass front.
9.Purging Air from Supply Line:
This should only be done by a qualified and li- censed (where applicable) professional. Check with your local building official for qualifications required to perform this procedure.
10.Purge air from the gas line (see #9 above), then connect propane gas line to the appliance. Connect the fuel line to the insert inlet (1/2” NPT fitting) using the fitting required.
11.Perform leak Test.
CAUTION
After this procedure is complete with appliance in- stalled and connected to gas line, recheck the pilot connection and manifold fittings for leaks, using soapy water or a gas leak detector.
12. Lighting
Note: If the gas control knob is turned to the “off” posi- tion after pilot has been lit, the appliance must be al- lowed to cool for at least five minutes before pilot flame can be relit.
13.Apply the propane conversion label to the rating label.
The Appliance is ready for use with propane fuel as its only fuel.
REFERENCE INFORMATION
See pages 4, 21 and 22 of this manual for the following reference information:
Manifold Gas Pressure Inlet Gas Pressure Input Ratings
BURNER FLAME APPEARANCE
A periodic visual check of burner flames should be performed. The burner flame should appear as indi- cated on page 17 - Burner Flame Appearance.
PAGE 15