![SPECIFICATIONS: Model L30 BF-2](/images/new-backgrounds/35443/3544343x1.webp)
SPECIFICATIONS: Model L30 BF-2
Approx. Sq. Ft.
Heating Capacity ∼ 1500 sq. ft.
Flue Size | 4” - Top Vent |
Height Overall | 29” |
Height to Flue |
|
Outlet | 30 3/8” |
Width | 29 7/8” |
Depth | 16 1/8” |
Fuel | Natural Gas (standard) |
| (or) LP Gas (convertible). |
| Gas inlet 3/8” |
| (or) remove flex, 3/8” |
Performance | Variable Flame Control. |
Features | High Efficiency Heat Exchanger. |
| Natural Convection & Radiant Heat. |
| Standing Pilot / Operates During Power |
| Outages. Remote Control & Wall |
| Thermostat Capable. |
Technical | Honeywell Combination Gas Control |
Features | Valve, Millivolt - VS8520E. Safety Shut |
| Down Sensor (Spill Switch). |
| Pan Burner with Tuned Ports. |
| Radiant & Fan Assisted Convection |
| Heat. |
Safety Test | Tested and certified by CSA to ANSI |
| standards. Z21.88 – (1998) • CSA 2.33 - |
| (1998). Vented Gas Fireplace Heater . |
Heat Input | 25,000 to 37,000 BTU’s (Nat. Gas) |
| 28,000 to 35,000 BTU’s (Propane) |
Ship Weight | 200 lb.’s |
Dimensions shown are approximations only (+ / - ¼”)
Top View
Side View
~Square feet heating capacities are approximations only. They will vary depending upon level of insulation, climate, house design, ceiling height, ambient outside tempera- tures and how stove is operated.
SPECIFICATIONS
GAS TYPE | NATURAL | PROPANE | CLEARANCES TO COMBUSTIBLES |
| |
| GAS | (LP) |
|
|
|
Orifice Size | #31 | Back Wall Min. | 2 In. / 51 mm | ||
Minimum Supply Pressure | 4.5” WC | 10.5” WC | Side Wall Min. | 12 | In. / 305 mm |
Maximum Supply Pressure | 10.5” WC | 13.0” WC | Corner (45° angle)s |
|
|
HIGH SETTING |
|
| stove corner to wall, min. | 4 In. / 102 mm | |
Manifold Pressure | 3.5” WC | 10.0” WC | Ceiling Height Minimum | 65 | In. / 1651 mm |
Input BTU / HR | 37,000 | 35,000 | Alcove Min. Height | 65 | In. / 1651 mm |
LOW SETTING |
|
| Alcove Min. width | 54 In. / 1372 mm | |
Mainfold Pressure | 1.8” WC | 6.6” WC | Alcove - Max. Depth into |
|
|
Input BTU / HR | 25,000 | 28,000 | stove face to alcove opening | 24 | In. / 610 mm |
♦ Altitude - U.S.A. |
| * With the orifice, manifold pressure and input | |||
♦ Altitude - Canada |
| ratings shown above. |
|
| |
For installation higher than altitudes shown above, reorifice per Gas |
|
|
| ||
Codes. |
|
|
|
|
|
This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must be field conversed using the LP Conversion Kit supplied with appliance.