SPECIFICATIONS: Model L30 BF-2

SPECIFICATIONS: Model L30 BF-2

Approx. Sq. Ft.

Heating Capacity 1500 sq. ft.

Flue Size

4” - Top Vent

Height Overall

29”

Height to Flue

 

Outlet

30 3/8”

Width

29 7/8”

Depth

16 1/8”

Fuel

Natural Gas (standard)

 

(or) LP Gas (convertible).

 

Gas inlet 3/8” NPT-Male / Flex Line

 

(or) remove flex, 3/8” NPT–Female Flare.

Performance

Variable Flame Control.

Features

High Efficiency Heat Exchanger.

 

Natural Convection & Radiant Heat.

 

Standing Pilot / Operates During Power

 

Outages. Remote Control & Wall

 

Thermostat Capable.

Technical

Honeywell Combination Gas Control

Features

Valve, Millivolt - VS8520E. Safety Shut

 

Down Sensor (Spill Switch).

 

Pan Burner with Tuned Ports.

 

Radiant & Fan Assisted Convection

 

Heat.

Safety Test

Tested and certified by CSA to ANSI

 

standards. Z21.88 – (1998) CSA 2.33 -

 

(1998). Vented Gas Fireplace Heater .

Heat Input

25,000 to 37,000 BTU’s (Nat. Gas)

 

28,000 to 35,000 BTU’s (Propane)

Ship Weight

200 lb.’s

Dimensions shown are approximations only (+ / - ¼”)

Top View

Side View

~Square feet heating capacities are approximations only. They will vary depending upon level of insulation, climate, house design, ceiling height, ambient outside tempera- tures and how stove is operated.

SPECIFICATIONS

GAS TYPE

NATURAL

PROPANE

CLEARANCES TO COMBUSTIBLES

 

 

GAS

(LP)

 

 

 

Orifice Size

#31 -.120

#50-.070”

Back Wall Min.

2 In. / 51 mm

Minimum Supply Pressure

4.5” WC

10.5” WC

Side Wall Min.

12

In. / 305 mm

Maximum Supply Pressure

10.5” WC

13.0” WC

Corner (45° angle)s

 

 

HIGH SETTING

 

 

stove corner to wall, min.

4 In. / 102 mm

Manifold Pressure

3.5” WC

10.0” WC

Ceiling Height Minimum

65

In. / 1651 mm

Input BTU / HR

37,000

35,000

Alcove Min. Height

65

In. / 1651 mm

LOW SETTING

 

 

Alcove Min. width

54 In. / 1372 mm

Mainfold Pressure

1.8” WC

6.6” WC

Alcove - Max. Depth into

 

 

Input BTU / HR

25,000

28,000

stove face to alcove opening

24

In. / 610 mm

♦ Altitude - U.S.A. 0-4,500 Ft. (0-1372M) No derating

 

* With the orifice, manifold pressure and input

♦ Altitude - Canada 0-4,500 Ft. (0-1372M) No derating

 

ratings shown above.

 

 

For installation higher than altitudes shown above, reorifice per Gas

 

 

 

Codes.

 

 

 

 

 

This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must be field conversed using the LP Conversion Kit supplied with appliance.