Lenoxx Electronics L30 BF-2 operation manual Installation Check List

Models: L30 BF-2

1 25
Download 25 pages 53.41 Kb
Page 11
Image 11
INSTALLATION CHECK LIST

INSTALLATION

INSTALLATION CHECK LIST

Read and understand these instructions before using appliance. Go through this installation checklist:

GEnsure that the log set is properly installed. Use cau- tion when handling the logs. See page 10.

GReinstall the door frame assembly. See Door Opera- tion on page 9.

WARNING: Do not operate appliance with the glass front removed, cracked or broken. Re- placement of the glass should be done by a qualified technician.

GEnsure venting termination cap is unobstructed.

GCheck to see that wiring is correct and is enclosed inside the stove pedestal base (See page 18).

GVerify that the gas line has been purged of air.

GTest all connections for leaks (factory and field) with a leak detector or soapy water solution. If you smell gas, do not attempt to light this appliance. Follow safety instructions on the front cover of this manual.

GBurner Air Shutter opening to be:

Natural Gas – 1/2 open, Propane 3/4 open.

Some adjustment from standard may be necessary for the desired flame characteristics (see Burner Flame Appearance, page 17). To adjust air shutter:

1.Remove burner from firebox by removing the 2 nuts as shown in the following picture. Then lift burner up and out of firebox.

2. Adjust gap as shown in following picture.

3.Reinstall burner. Do not overtighten nuts (finger tight only).

GLight the appliance following the instructions on page 13 (Care and Operation). Relight the main burner in both the HI, and LO positions, and verify proper burner ignition and operation.

NOTE: Upon the initial firing of your new gas stove, you will notice a strong odor. This will last up to two hours. It is recommended to open the windows to allow fresh air to circulate into the room.

WARNING: If the pilot does not light after 1 min- ute, wait at least 5 minutes for gas to clear before attempting again.

GWith burner lit, check to make sure that the inlet gas and manifold pressures are correct (see Gas Pres- sure, page 4). Verify that the pilot and main burner ignition and operation are correct.

PAGE 11

Page 11
Image 11
Lenoxx Electronics L30 BF-2 operation manual Installation Check List