Set server parameter values

Response: HTTP/1.0 200 OK\r\n Content-Type: text/html\r\n Context-Length: 33\r\n \r\n network.ipaddress=192.168.0.123\r\n

Set server parameter values

Note: This request require administrator access

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/admin/setparam.cgi? [nosync=<value>&]<parameter>=<value> [&<parameter>=<value>…][&return=<return page>]

parameter

value

description

 

 

 

<group>_<name>.

value to assigned

Assign <value> to the parameter <group>_<name>..

return

<return page>

Redirect to the page <return page> after the parameter

 

 

is assigned. The <return page> can be a full URL path

 

 

or relative path according the the current path. If you

 

 

omit this parameter, it will redirect to an empty page.

 

 

(note: The return page can be a general HTML

 

 

file(.htm, .html) or a server script executable (.vspx)

 

 

file. It can not be a CGI command. It can not have any

 

 

extra parameters. This parameter must be put at end of

 

 

parameter list)

 

 

 

Return:

HTTP/1.0 200 OK\r\n Content-Type: text/html\r\n Context-Length: <length>\r\n \r\n

<parameter pair>

where <parameter pair> is