Sharp PG-D100U operation manual Installing the lamp unit, Resetting the lamp timer

Models: PG-D100U

1 38
Download 38 pages 44.23 Kb
Page 33
Image 33
Installing the lamp unit

Caution:

Because some parts may not be sufficiently cooled, be sure to remove the lamp cage by the handle while taking care not to touch the metallic areas.

Note:

Do not allow anything to hit the UV filter (j).

Installing the lamp unit

1.Hold lamp cage (h) by the handle (g) and press it in firmly while making sure that the lamp cage (h) properly connects to the connector (i).

2.Tighten screws (e), (f) and (d), then perform the above instructions in the reverse order.

Resetting the lamp timer

OFF Resetting the lamp timerManual background ON

OFF Manual background ON

MN EN

LAMP

0000H

1. Plug in the power cord.

2.While depressing the ADJUSTMENT Manual background , ADJUSTMENT Manual background, and ENTER buttons on the projector, turn on the MAIN POWER switch.

3.Press the POWER ON/OFF button on the projector or the power on button on the remote control to turn on the power.

After the unit projector turns on, “LAMP 0000H” will be displayed to signify that the lamp timer is reset.

Notes:

After replacing lamp, be sure to reset the lamp timer. If you do not, the LAMP REPLACEMENT indicator and “LAMP” display will not disappear.

Only reset the lamp timer after replacing the lamp.

E-33