PROBE LENGTHS
B G A C
WATER LEVEL
PROBES
A G
RED
BLK
C B
GRN
ON/OFF TOGGLE SWITCH
RED
RED
BLK
BLK
RED
GRN
| G |
L | H |
NC COM NO | LLCO |
| |
| RED |
L1
120V IN
DUAL PRESSURE
CONTROLS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C NO NC |
| C NO NC | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
OPTIONAL
MANUAL LOW- WATER RESET
BLK
BLK
BLUE
| RESET |
| PC BOARD | |||||
|
| |||||||
|
| |||||||
|
| |||||||
|
|
| NO |
| COM |
| NC |
|
|
|
|
|
|
| |||
|
|
|
|
| G | |||
|
|
|
|
|
|
|
L2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
YEL |
|
|
|
| RED |
HIGH VOLTAGE IN
28 of 33
PPL |
| BLUE |
BLUE
BLK
YEL
1/4HP PUMP & MOTOR HIGH PRESSURE ONLY
BLK
YEL
YEL
BLK
WATER SOLENOID
YEL
BLUE
L1 | L2 | L3 |
CONTACTOR
T1 T2 T3
YEL | YEL | |
BLUE | ||
|
GRND
This drawing and all information therein are the property of
DRAWING TITLE: LG (H) |
| MODEL UNIT: LG |
|
| ||
DECRIPTIONS: | DRAWN BY: | CHRISTOPHER FERRARA |
|
| ||
HIGH PRESSURE | CHECKED: | SAL NEGRO |
|
| ||
- | ENGINEER: | CHRISTOPHER FERRARA | SCALE: N/A | |||
- | APPROVED: | JOHN PARDINI | SHEET: 1 OF 1 | |||
|