1.) INSTALLATION INSTRUCTIONS
LITTLE GIANT
The
IMPORTANT – READ ALL INSTRUCTIONS BEFORE OPERATING
Important – Set unit perfectly level, and as close as possible to the steam vessel or appliance it will operate. For generator measurements, refer to Installation Data Drawing attached. For interpretation of numbered items, refer to Parts Legend Drawing attached. NOTE: Ambient temperature around this unit must not exceed 105°F.
CONNECTIONS:
Periodically check all plumbing and electrical connections for tightness; this should also be done before initial
ELECTRICAL:
This generator must be connected to a disconnect switch protected by fuses or circuit breakers with the proper size wire by a licensed electrician in accordance with N.E.C. and your local codes – Voltage, KW, and Phase requirement are marked on the nameplate.
WATER SUPPLY:
Connect city water line to
*CAUTION: The Pump (#8) requires clean tap water. If the water is not free of foreign matter, a 5 micron cartridge filter should be installed in the water supply line.
STEAM OUTLET:
Connect Steam Outlet Valve (#16) to piece of equipment, vessel, room, or area to be operated by the Electro Steam Generator.
SAFETY VALVE & DRAIN:
Separately route the Safety Valve (#18) & Drain (#23) to a high temperature drain *NO PVC. Discharging pipe of the Safety Valve (#18) should never be smaller than the valve outlet and should be rigidly supported, placing no weight on the safety valve itself. If equipped with Motorized
4 of 33