3.4.2) BRASS SIGHT GLASS (SEISMIC)

LG-10 thru LG-30 - User Manual

Electro-Steam Generator Corp.

3.4) REPLACING GLASS GAUGE & RUBBER WASHERS OR GLASS PACKINGS (Continued)

The Sight Glass (#10) gives the operator the ability to easily monitor the actual water level inside the chamber. If the Sight Glass (#10) gets clogged or is no longer functional, it can be very difficult to troubleshoot a problem.

3.4.2) BRASS SIGHT GLASS (SEISMIC)

GLASS GAUGE and GLASS PACKINGS MUST be replaced EVERY SIX MONTHS

The Seismic Sight Glass is equipped with BALL

CHECKS in each GAUGE FITTING.

INSTALLATION:

Only properly trained personnel should install and maintain water gauge glass and connections. Remember to wear safety gloves and glasses during installation. Before installing, make sure all parts are free of chips and debris.

1.Uninstall GUARD RODS, GLASS GAUGE, and GLASS PACKINGS. (You may need to rotate one of the GAUGE FITTINGS to remove GLASS GAUGE)

2.Slip a new GLASS PACKINGS on the new GLASS GAUGE about an inch from the bottom.

3.Now slip the following items through the top of GLASS GAUGE in the following order:

PACKING GLAND (facing down)

GLASS PACKING NUT (facing down)

GLASS PACKING NUT (facing up)

PACKING GLAND (facing up)

GLASS PACKINGS (inch down from top)

PACKING WASHER

4.Gently insert GLASS GAUGE into GAUGE FITTINGS. You may need to rotate GAUGE FITTINGS until vertically aligned, after GLASS GAUGE is in.

5.Carefully raise GLASS GAUGE about 1/16” from bottom and slide lower GLASS PACKINGS down until it makes contact with the BOTTOM GAUGE FITTING. (DO NOT allow GLASS GAUGE to remain in contact with any metal)

6.Carefully slide upper GLASS PACKINGS up as far as possible.

7.Hand tighten both GLASS PACKING NUTS, then tighten 1/2 turn more by wrench. Tighten only enough to prevent leakage. DO NOT OVER TIGHTEN! If any leakage should occur, tighten slightly, a quarter turn at a time, checking for leakage after each turn.

8.Reinstall GUARD RODS.

9 of 33

Page 9
Image 9
LG Electronics Brass Sight Glass Seismic, LG-10 thru LG-30 - User Manual, Electro-Steam Generator Corp, Packing Washer