CONTROLLING THE MULTIPLE PRODUCT 43
ENG
ENGLISH
26. Natural Mode (In Tile mode)(Command: d j)
To assign the Tile Natural mode for Tiling function.
Transmission
[d][j][ ][Set ID][ ][Data][x]
Data 0 : Natural Off
1 : Natural On
ff : Read Status
Acknowledgement
[j][ ][Set ID][ ][OK/NG][Data][x]
27. Picture Mode (Command: d x)
To adjust the picture mode.
Transmission
[d][x][ ][Set ID][ ][Data][x]
Data Structure
Data(Hex) Mode
00 Vivid
01 Standard
02 Cinema
03 Sport
04 Game
05 User1
06 User2
Acknowledgement
[x][ ][Set ID][ ][OK/NG][Data][x]
28. Sound Mode (Command: d y)
To adjust the Sound mode.
Transmission
[d][y][ ][Set ID][ ][Data][x]
Data Structure
Data(Hex) Mode
00 Clear Voice
01 Standard
02 Music
03 Cinema
04 sport
05 Game
06 User
Acknowledgement
[y][ ][Set ID][ ][OK/NG][Data][x]
29. Fan Fault check (Command: d w)
To check the Fan fault of the Set.
Transmission
[d][w][ ][Set ID][ ][Data][x]
* The data is always FF (in Hex).
Data ff : Read Status
Acknowledgement
[w][ ][Set ID][ ][OK/NG][Data][x]
* Data is the status value of the Fan fault.
Data 0 : Fan fault
1 : Fan Ok
2 : N/A (Not Avaliable)
30. Elapsed time return (Command: d l)
To read the elapsed time.
Transmission
[d][l][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[l][ ][Set ID][ ][OK/NG][Data][x]
* The data is always FF(in Hex).
(Hexadecimal code)
31. Temperature value (Command: d n)
To read the inside temperature value.
Transmission
[d][n][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.