Connecting electric dryers (cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Four-wire connection for electric dryers: Direct wire

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove 5 inches (12.7 cm) of the outer covering from the wire. Remove 5 inches of insulation from the ground wire. Cut off approximately 11inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape.

1" (2.5 cm)

Ground Wire

5"

(12.7 cm)

2.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

4-Wire Power

Cord

Use UL-listed4-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.

3.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cable to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cable ground wire to the green ground screw. Tighten aLl screws securely. Reinstall the terminal block access cover.

Hot

Neutral

(Black)

(White)

 

Hot

Ground

(Red)

 

Screw

 

 

White Wire

 

moved from

Power Cord

Ground Screw

 

Ground Wire

 