LG Electronics DLE1101W, DLG1102W Restricted or blocked airflow, TE1 or tE2, PS or PF or nP

Models: DLG1102W DLE1101W

1 80
Download 80 pages 8.73 Kb
Page 28
Image 28

28INSTALLATION INSTRUCTIONS

Installation test (Duct check) (cont.)

• Check the error code before you call for service

Error Code

Possible Causes

 

Solutions

 

 

 

 

tE1 or tE2

Temperature sensor failure

Turn off the

dryer and call for

 

service.

 

 

 

 

 

 

 

 

HS

Humidity sensor failure.

Turn off the

dryer and call for

 

service.

 

 

 

 

 

 

 

 

Electric dryer power cord is not

Check the power supply or the

 

connected correctly, or house power

connection of power cord to the

 

supply is incorrect.

terminal block. Refer to the

 

 

Connecting electric dryers section of

 

House fuse is blown, circuit breaker has

this manual for complete instructions.

PS or PF or nP

tripped, or power outage has occurred.

• Reset circuit breaker or replace fuse.

 

 

Do not increase the fuse capacity.

 

 

If the problem is a circuit overload,

 

 

have it corrected by a qualified

 

 

electrician.

 

 

 

 

 

Check the duct condition

If the test displays four bars, check the exhaust system for re- strictions and damage. Repair or replace the exhaust system as needed.

NOTE

When the dryer is first installed, this test should be performed to alert you to any existing problems with the exhaust duct in your home. However, since the test performed during normal operation provides more accurate information on the condition of the exhaust duct than does the installation test, the number of bars displayed during the two tests may not be the same.

Do not interrupt the test cycle, as this could result in the wrong results.

Even if no bars are displayed during the test cycle, some restrictions may still be present in the exhaust system. Refer to the Venting the Dryer section of this manual for complete exhaust system and venting requirements.

Your dryer features Flow Sense™, an innovative sensing system that automatically detects blockages and restrictions in dryer ductwork. Keeping ductwork clean of lint buildup and free of restrictions allows clothes to dry faster and reduces energy use.

Restricted or blocked airflow

Avoid long runs or runs with multiple elbows or bends.

Excess or crushed

Too many elbows or

transition duct

exhaust too long

Check for blockages and lint buildup.

Lint

buildup or

blockage

Make sure the ductwork is not crushed or restricted.

Crushed or

damaged

exhaust

Page 28
Image 28
LG Electronics DLE1101W, DLG1102W Restricted or blocked airflow, TE1 or tE2, PS or PF or nP, Check the duct condition