Installation

SelectTheBest Location

Indoor unit

1.Do not have any heat or steam near the unit.

2.Select a place where there are no obstacles in front of the unit.

3.Make sure that condensation drainage can be conveniently routed away.

4.Do not install near a doorway.

5.Ensure that the space around the left and right of the unit is more than 30cm(11.8in). The unit should be installed as high on the wall as possi- ble, allowing a minimum of 12cm(4.7in) from ceiling.

6.Use a stud finder to locate studs to prevent unnecessary damage to the wall.

 

More than

More than

12cm(4.7in)

 

30cm(11.8in)

 

 

More than

 

30cm(11.8in)

More than 8ft(2.4m)

 

Install the indoor unit on the wall where the height from the floors more than 2.3meters(7.6ft). A minimum pipe run of 7.5meters(24.6ft) is required to minimize vibration and excessive noise.

Outdoor unit

1.

If an awning is built over the unit to prevent

 

direct sunlight or rain exposure, make sure that

 

heat radiation from the condenser is not

 

restricted.

2.

Ensure that the space around the back and

 

sides is more than 10cm(3.9in). The front of the

 

unit should have more than 70cm(27.6in) of

 

space.

5.Select a place so that the warm air and noise from the air conditioner do not disturb neigh- bors.

More than 60cm(23.6in)

More than

More than

3. Do not place animals and plants in the path of

the warm air.

10cm(3.9in)

10cm(3.9in)

4. Take the air conditioner weight into account and

select a place where noise and vibration are

minimum.

More than

More than

70cm(27.6in)

60cm(23.6in)

 

Rooftop Installations

If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.

If the outdoor unit is installed on roof structures or walls, this may result in excessive noise and vibra- tion, and may be also classed as non serviceable installation.

Copyright ©2007 LG Electronics. Inc. All right reserved.

- 17 -

Only for training and service purposes

LGE Internal Use Only

 

Page 17
Image 17
LG Electronics LS180CP(AS-C183DM0) manual Select The Best Location, Indoor unit, Outdoor unit, Rooftop Installations