RS-232C

 

Controlling Multiple Set

 

 

 

Transmission / Receiving Protocol

Transmission

[Command1][Command2][ ][Set ID][ ][Data][Cr]

*[Command 1]: First command. (k, j, m, d, f, x)

*[Command 2]: Second command.(a to u)

*[Set ID]: Set up the Set ID number of product.

range : 01H to 63H. by setting '0', server can control all products.

*In case of operating with more than 2 sets using set ID as '0' at the same time, it should not be checked the ack message. Because all sets will send the ack message, so it's impossible the check the whole ack messages.

*[DATA]: To transmit command data.

Transmit 'FF' data to read status of command.

*[Cr]: Carriage Return ASCII code '0 x 0 D'

* [ ]: ASCII code Space (0 x 20)

OK Acknowledgement

[Command2][ ][Set ID][ ][OK][Data][x]

*The Product transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data.

If the data is data write mode, it returns the data of the PC computer.

Error Acknowledgement

[Command2][ ][Set ID][ ][NG][Data][x]

* If there is error, it returns NG

A4

Page 57
Image 57
LG Electronics M3204C owner manual Transmission / Receiving Protocol