Cornelius IWC522, IAC 322, IAC227, CR800, CR1200 IAC 830, IWC 830 & IRC, IAC 630, IWC 630 & IRC

Models: IAC530 IWCS227 IWC522 IAC522 IAC330 IWC322 IWC330 IWC530 CR1400 CR1200 CR800 IAC227 IAC 322

1 83
Download 83 pages 13.44 Kb
Page 62
Image 62
IAC 830, IWC 830 & IRC 830

 

 

LIQUID LINE

 

 

RD

 

 

 

 

RD

 

 

 

 

RD

 

 

 

 

SOLENOID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(R/C ONLY)

 

 

 

 

 

COMPRESSOR

COMPRESSOR

GR

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

RUN

 

START

 

CONTACTOR

 

RD

 

 

COMPRESSOR

 

 

 

 

 

CAPACITOR

CAPACITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

BR

 

 

 

RD

 

RD

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See note 2

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

35 mfd

 

 

 

 

 

 

BK

 

 

 

YL

 

145-174 mfd

 

 

 

 

 

 

 

 

 

 

370 VAC

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250 VAC

 

 

 

 

 

 

 

 

EXTERNAL

YL

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

RD

 

 

M

 

 

 

OVERLOAD

 

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRANKCASE

 

 

 

 

 

 

 

 

 

 

 

RD

HEATER

 

 

 

 

 

 

 

BR

 

 

2

BK

BL

 

 

 

 

 

 

5

 

(RC ONLY)

BK

CONDENSATION FAN

 

POTENTIAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(W/C & R/C ONLY)

 

 

START RELAY

1

 

 

 

 

 

 

 

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL RESET

 

 

 

 

 

 

 

 

 

HIGH PRESSURE CONTROL

 

 

 

 

 

 

 

 

 

 

(W/C & RC ONLY)

 

 

 

RD

 

 

 

 

 

 

 

 

 

WATER DUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO

 

 

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

BR

450 PSIG

 

BL

BK

 

 

 

 

WH

 

 

 

 

 

 

 

 

 

UNIT

 

BR

 

 

1

 

WATER DUMP

 

 

 

 

SWITCH

 

 

 

3

2

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

M

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

CONDENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

 

 

D-15GR

Water

 

 

 

 

(A/C ONLY)

 

 

WH

 

 

 

 

 

 

 

 

 

Dump

 

 

 

 

 

 

 

 

 

D-13

 

Valve

 

 

 

 

 

 

 

 

 

D-14

 

 

 

 

 

 

 

 

 

 

RH Evap.

YL

 

 

 

7

8

 

 

 

 

 

GR

Relay

 

 

BL

 

 

 

Switch

 

 

 

 

 

 

RH Evap.

 

 

 

5

6

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

GR

Water

 

3

4

RD

 

 

 

 

 

D-10

Pump

 

 

 

 

 

 

D-12

 

1

2

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

LH Evap.

 

 

 

 

 

 

 

 

WH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

WH

Switch

LH Evap.

D-11

 

 

 

 

 

 

 

N

 

Hot Gas

 

 

 

 

 

 

 

S

 

 

GR

 

 

 

 

 

 

 

 

 

 

 

Valve

 

 

 

 

 

PUMP

 

(White Lead)

 

 

 

230V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condenser Sensor Condenser

 

 

 

Voltage

 

 

 

 

CORD

 

 

Plug

 

 

 

 

 

 

 

 

 

 

See note 1

 

 

 

 

Selector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction

D-6

 

 

Switch

 

 

HOT GAS

 

 

 

 

 

 

Condenser

 

 

 

 

 

 

Plug

 

GR

 

 

 

 

 

 

Suction Line

 

 

Fan

 

 

 

SOLENOID

 

 

 

 

 

 

 

115V

 

 

 

 

 

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

(Brown Lead)

Test

RD D-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

Error

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug

Adjustable Ice

 

Transformer

 

 

 

 

WATER PUMP

 

 

Thickness Pot.

 

 

 

 

 

 

 

 

To Stacked

Micro

 

 

 

Processor

 

 

 

Unit

 

 

 

 

 

 

 

(if required)

Stacking

 

 

 

 

 

 

 

 

Cable

Manual

 

 

 

Plug

Harvest

 

IAC 830, IWC 830 & IRC 830

 

 

Switch

 

 

 

 

BL

IAC 630, IWC 630 & IRC 630

 

 

 

 

NOTE 1: CONDENSER SENSOR USED ONLY ON A/C UNITS.

1.8K ohm RESISTER USED ONLY ON W/C & R/C UNITS.

NOTE 2: CAPACITORS USED ON 630 BRISTOL COMPRESSOR:

RUN CAP, 25mfd 440 VAC

START CAP. 161-193mfd 250 VAC

12/1/94

59

166240004

Rev 3/4/96

 

 

Page 62
Image 62
Cornelius IWC522, IAC 322, IAC227, CR800, CR1200, CR1400, IWC530, IWC330, IWC322 IAC 830, IWC 830 & IRC, IAC 630, IWC 630 & IRC