Cornelius IWC530, IAC 322, IAC227, CR800 Remote Condenser Specification, Ice Cuber Specification

Models: IAC530 IWCS227 IWC522 IAC522 IAC330 IWC322 IWC330 IWC530 CR1400 CR1200 CR800 IAC227 IAC 322

1 83
Download 83 pages 13.44 Kb
Page 5
Image 5
REMOTE CONDENSER SPECIFICATION

REMOTE CONDENSER SPECIFICATION

MODEL

CR800

CR1200

CR1400

Volts

208/230

208/230

208/230

Phase

1

1

1

Hertz

60

60

60

Amps

1.0

1.0

1.0

Output, HP

1/6

1/6

1/6

Max. fuse size, Amps (HVAC circuit breaker

20

20

20

required)

 

 

 

 

 

 

 

ICE CUBER SPECIFICATION

MODEL

IAC322/330

IAC227

IWC322/330

IWCS227

IAC522/530

IWC522/530

UNIT

Volts

Phase

Hertz

No. Wires

115

1

60

2+ground

115

1

60

2+ground

115

1

60

2+ground

115

1

60

2+ground

MIN. CIRCUIT

Amps

20

20

 

 

 

MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)

Amps

20

20

REFRIGERANT

20

20

20

20

Type

Weight (oz)

Weight (g)

COMPRESSOR

Volts

Phase

Hertz

LRA

RLA

R404A (HP62)

17

482

115

1

60

51

11.5

R404A (HP62)

15

425

115

1

60

51

11.5

R404A (HP62)

26

737

115

1

60

59

11.6

R404A (HP 62)

23

652

115

1

60

59

11.6

CONDENSER FAN MOTOR (Air-Cooled Systems only) of

AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)

Volts

Phase

Hertz

Amps Running Watts

WATER PUMP

115

1

60

1.7

50

115

1

60

0.38

6

115

1

60

1.75

50

115

1

60

0.38

6

Volts

115

115

115

Phase

1

1

1

Hertz

60

60

60

Amps Running

0.88

0.88

0.76

HP

1/40

1/40

1/40

 

 

 

 

115

1

60

0.88

1/40

166240004

2

12/1/94

Rev 3/4/96

 

 

Page 5
Image 5
Cornelius IWC530 Remote Condenser Specification, Ice Cuber Specification, CONDENSER FAN MOTOR Air-Cooled Systems only of