Cornelius IWC330, IAC 322, IAC227, CR800, CR1200 SPECIFICATIONS - 60 HZ, Ice Cuber Specification

Models: IAC530 IWCS227 IWC522 IAC522 IAC330 IWC322 IWC330 IWC530 CR1400 CR1200 CR800 IAC227 IAC 322

1 83
Download 83 pages 13.44 Kb
Page 6
Image 6
SPECIFICATIONS – 60 HZ

12/1/94 Rev 3/4/96

SPECIFICATIONS – 60 HZ

ICE CUBER SPECIFICATION

 

IAC322E60

IWC322E60

IAC522E60

IWC522E60

 

IAC522E60L

IWC522E60L

MODEL

IAC330E60

IWC330E60

IAC530E60

IWC530E60

 

IACS227E60

IWCS227E60

 

IAC530E60L

IWC530E60L

 

 

 

 

 

 

 

 

UNIT

Volts

Phase

Hertz

No. Wires

MIN. CIRCUIT

230

1

60

2+ground

230

1

60

2+ground

230

1

60

2+ground

230

1

60

2+ground

3

Amps

15

 

15

15

15

MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)

 

 

 

Amps

 

 

15

 

 

15

 

15

15

REFRIGERANT

 

 

 

 

 

 

 

 

 

 

Type

R404A(HP62)

 

R404A(HP62)

R404A(HP62)

R404A(HP 62)

Weight (oz)

17

 

15

26

23

Weight (g)

482

 

425

737

652

COMPRESSOR

 

 

 

 

 

Volts

230

230

Phase

1

1

Hertz

60

60

LRA

24.1

24.1

RLA

5.7

5.7

 

 

 

CONDENSER FAN MOTOR (Air-Cooled Systems only) or

AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)

230

1

60

45

9.2

230

1

60

45

9.2

Volts

Phase

Hertz

Amps Running Watts

WATER PUMP

230

1

60

0.89

50

230

1

60

0.36

6

230

1

60

0.89

50

230

1

60

.036

6

166240004

Volts

Phase

Hertz

Amps Running

HP

230

1

60

0.5

1/30

230

1

60

0.5

1/30

230

1

60

0.5

1/30

230

1

60

0.5

1/30

Page 6