Cornelius IAC522, IAC 322, IAC227, CR800, CR1200, CR1400 Installation Instructions Remote Condensers

Models: IAC530 IWCS227 IWC522 IAC522 IAC330 IWC322 IWC330 IWC530 CR1400 CR1200 CR800 IAC227 IAC 322

1 83
Download 83 pages 13.44 Kb
Page 74
Image 74
INSTALLATION INSTRUCTIONS REMOTE CONDENSERS

INSTALLATION INSTRUCTIONS REMOTE CONDENSERS

UNIT

1/4-20 SCREW

 

LEG

BRACE

LEG

1.Follow the standard installation instructions supplied with cuber. Do not hook cuber into the power source until the remote condenser and line set installation is complete.

2.Assembly of remote condenser (see drawing):

A.Assemble legs to base panel. Install leg supports on legs.

B.Locate the remote condenser in a well–ventilated area on the roof away from other refrigeration equip- ment’s condenser discharge air flow.

C.Use the mounting holes provided to secure the remote condenser to the roof. Seal over heads of bolts or fasteners with tar or pitch to prevent entrance of moisture.

REMOTE CONDENSER

LEG

LEG SUPPORT

3.Remote condenser electrical hook-up:

A.Connect remote condenser to a power source (208/230VAC, 60 HZ) separate from the cuber. An ex- ternal disconnect switch must be used.

B.Make sure the electrical connections follow all local and national codes.

C.DO NOT turn condenser on until cuber install and refrigerant line connections are complete!

D.Never wire condenser into cuber section. The condenser is an independent electrical connection.

E.Fan motor will not start until pressure rises to 205 PSIG [14.07 Bars] closing fan cycling switch.

12/1/94

71

166240004

Rev 3/4/96

 

 

Page 74
Image 74
Cornelius IAC522, IAC 322, IAC227, CR800, CR1200, CR1400, IWC530, IWC330, IWC322 Installation Instructions Remote Condensers